CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsui, B. C.H.
Right arrow Articles by Finucane, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsui, B. C.H.
Right arrow Articles by Finucane, B.
Related Collections
Right arrow Regional Anesthesia and Pain
Canadian Journal of Anesthesia 47:471-473 (2000)
© Canadian Anesthesiologists' Society, 2000

Brief Clinical Report

Detection of subdural placement of epidural catheter using nerve stimulation

Ban C.H. Tsui , MSc MD, Sunil Gupta, MD FRCP, Derek Emery, MD FRCP* and Brendan Finucane , MBBCH FRCP

From the Department of Anesthesiology and Pain Medicine, and the Department of Diagnostic Imaging,
* University of Alberta Hospitals, Walter Mackenzie Health Sciences Centre, 8440-112 Street, Edmonton, Alberta, T6G 2B7 Canada.

Address Dr. Ban C.H. Tsui. Phone: 780-407-8861; Fax: 780-407-3200; E-mail: btsui{at}ualberta.ca

Objectif : Rapporter la détection du positionnement d'un cathéter sous-dural à l'aide de la neurostimulation au travers d'un cathéter péridural.

Éléments cliniques : Une cystectomie radicale avec création d'un canal iléal a été prévue chez un homme de 85 ans. On a choisi une anesthésie générale combinée à une technique régionale. Un cathéter péridural (19 G Arrow Flextip Plus) a été inséré avant l'induction de l'anesthésie générale. Pendant l'opération, le patient a reçu 5 mg de morphine et 10 ml de bupivacaïne à 0,5 % au travers du cathéter péridural. La stabilité hémodynamique s'est maintenue pendant l'intervention et le patient n'a pas eu besoin d'opioïdes intraveineux. Le patient a quitté le service avec une prescription de morphine péridurale contre la douleur. Le jour suivant, il se portait toujours bien. Afin d'étudier le taux de réussite de l'usage de cathéters périduraux à notre institution, nous procédons à une analyse permanente de la qualité, invitant les patients à faire évaluer leur cathéter au moyen de test de neurostimulation. La stimulation électrique (1-10 mA), par une réponse motrice segmentaire (mouvement du tronc ou des extrémités), indique si le cathéter est dans l'espace péridural. L'absence de réponse motrice indique qu'il ne l'est pas. Dans le cas présent, un positionnement sous-dural du cathéter est envisagé parce qu'une réponse motrice diffuse, incluant la paroi thoracique antérieure droite, les muscles du dos et les extrémités inférieures bilatérales, a été observée en utilisant un courant de seulement 0,3 mA. La position sous-durale a été confirmée par une radiographie ultérieure montrant une très mince couche de colorant qui s'étendait en direction céphalique et caudale sur de nombreux segments.

Conclusion : Ce nouveau test électrique aide à détecter objectivement le placement sous-dural d'un cathéter.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
B. C. H. Tsui
Epidural stimulation test criteria.
Anesth. Analg., September 1, 2006; 103(3): 775 - 776.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. C. H. Tsui
Is It Time to Perform All Thoracic Epidural Placements Under Fluoroscopy?
Anesth. Analg., May 1, 2006; 102(5): 1586 - 1586.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
B. C. H. Tsui
Epidural stimulation test vs epidural ECG test for checking epidural catheter placement
Br. J. Anaesth., December 1, 2005; 95(6): 837 - 837.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
P. Lena and R. Martin
Subdural placement of an epidural catheter detected by nerve stimulation: [Positionnement sous-dural d'un catheter epidural detecte par stimulation nerveuse et confirme par tomographie]
Can J Anesth, June 1, 2005; 52(6): 618 - 621.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. C.H. Tsui, A. M. Wagner, K. Cunningham, S. Perry, S. Desai, and R. Seal
Threshold Current of an Insulated Needle in the Intrathecal Space in Pediatric Patients
Anesth. Analg., March 1, 2005; 100(3): 662 - 665.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
S. A. Lang, C. Prusinkiewicz, and B. C.H. Tsui
Failed spinal anesthesia after a psoas compartment block: [L'echec de la rachianesthesie apres le bloc de la loge du psoas]
Can J Anesth, January 1, 2005; 52(1): 74 - 78.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. Singh, C. Papneja, V. Datt, B. C. H. Tsui, and S. Malherbe
Reversal of an Unintentional Spinal Anesthetic by Cerebrospinal Lavage * Response
Anesth. Analg., January 1, 2005; 100(1): 296 - 297.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. C. H. Tsui, A. Wagner, D. Cave, and R. Seal
Threshold Current for an Insulated Epidural Needle in Pediatric Patients
Anesth. Analg., September 1, 2004; 99(3): 694 - 696.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
B. C.H. Tsui, A. Wagner, and B. Finucane
The threshold current in the intrathecal space to elicit motor response is lower and does not overlap that in the epidural space: a porcine model: [Le courant seuil qui produit une reponse motrice est plus faible dans l'espace intrathecal que dans l'espace peridural et ne le chevauche pas: un modele porcin]
Can J Anesth, August 1, 2004; 51(7): 690 - 695.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. A. Lang, B. Tsui, T. Grau, T. Kasai, K. Yaegashi, H. Hirose, and Y. Tanaka
New Avenues of Epidural Research * Response
Anesth. Analg., July 1, 2003; 97(1): 292 - 293.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. C.H. Tsui, B. Finucane, and K. Hayatsu
Verifying Accurate Placement of an Epidural Catheter Tip Using Electrical Stimulation * Response
Anesth. Analg., June 1, 2002; 94(6): 1670 - 1671.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. C. H. Tsui, R. Seal, J. Koller, L. Entwistle, R. Haugen, and R. Kearney
Thoracic Epidural Analgesia Via the Caudal Approach in Pediatric Patients Undergoing Fundoplication Using Nerve Stimulation Guidance
Anesth. Analg., November 1, 2001; 93(5): 1152 - 1155.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsui, B. C.H.
Right arrow Articles by Finucane, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsui, B. C.H.
Right arrow Articles by Finucane, B.
Related Collections
Right arrow Regional Anesthesia and Pain


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the Canadian Anesthesiologists' Society.