CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lu, P.-P.
Right arrow Articles by Shyr, M.-H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lu, P.-P.
Right arrow Articles by Shyr, M.-H.
Related Collections
Right arrow Cardiothoracic Anesthesia, Respiration and Airway
Canadian Journal of Anesthesia 47:849-853 (2000)
© Canadian Anesthesiologists' Society, 2000

Reports of Investigation

The intubating LMA: a comparison of insertion techniques with conventional tracheal tubes

Pao-Ping Lu, MD, Chen-Hsien Yang, MD, Angie C.Y. Ho, MD and Ming-Hwang Shyr, MD PhD

From the Department of Anaesthesia, Chang Gung Memorial Hospital, 5 Fu-hsing Street, Kwei-shan, Taoyuan 333, Taiwan, Republic of China.

Address correspondence to: Ming-Hwang Shyr MD PhD, Phone: 886-3-3281200, Ext. 2324; Fax: 886-3-3342068; E-mail: an001{at}adm.cgmh.com.tw

Objectif : Comparer le fonctionnement du masque laryngé d'intubation (MLI) utilisé avec des tubes endotrachéaux de différentes courbures, pour faciliter l'intubation endotrachéale à l'aveugle, et la fréquence de complications possibles.

Méthode : Ayant donné leur consentement éclairé, 240 adultes d'état physique ASA I-II devant subir une intervention planifiée ont participé à un essai clinique randomisé et à l'insu. L'intubation, à l'aveugle avec le MLI et un tube endotrachéal de courbure habituelle (groupe normal) ou par insertion inversée (groupe inversé), était notée comme un échec si elle exigeait plus de trois essais. On a enregistré la plus faible saturation en oxygène pendant l'intubation et évalué, selon une échelle verbale analogique, le mal de gorge et la raucité de la voix qui ont pu suivre l'intubation.

Résultats : Le taux de succès de l'intubation n'a pas présenté de différence intergroupe significative (96,7 % et 94,2 % respectivement). Une intubation réussie au premier essai a été plus fréquente dans le groupe inversé que dans le groupe normal (86,7 % vs 75,0 %, P=0,033). L'incidence de mal de gorge a été plus élevée dans le groupe normal que dans le groupe inversé (19,2 % vs 9,2 % respectivement, P =0,042).

Conclusion : L'intubation endotrachéale à l'aveugle avec un MLI et un tube endotrachéal de courbure habituelle est possible et fréquemment réussie. L'insertion par inversion de la courbure, préférable au premier essai d'intubation, présente un meilleur taux de réussite et moins de complications.




This article has been cited by other articles:


Home page
Br J AnaesthHome page
A. Nileshwar and A. Thudamaladinne
Comparison of intubating laryngeal mask airway and Bullard laryngoscope for oro-tracheal intubation in adult patients with simulated limitation of cervical movements
Br. J. Anaesth., August 1, 2007; 99(2): 292 - 296.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
P. Kundra, N. Sujata, and M. Ravishankar
Conventional Tracheal Tubes for Intubation Through the Intubating Laryngeal Mask Airway
Anesth. Analg., January 1, 2005; 100(1): 284 - 288.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
H. S. Joo, M. T. Kataoka, R. J.B. Chen, J. Doyle, and C. D. Mazer
PVC tracheal tubes exert forces and pressures seven to ten times higher than silicone or armoured tracheal tubes - an in vitro study: [Les tubes tracheaux de PVC exercent des forces et des pressions de sept a dix fois plus elevees que les tubes en silicone ou les tubes armes - une etude in vitro]
Can J Anesth, November 1, 2002; 49(9): 986 - 989.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
P.-P. Lu, J. Brimacombe, A. C. Y. Ho, M.-H. Shyr, and H.-P. Liu
The intubating laryngeal mask airway in severe ankylosing spondylitis : [L'utilisation du masque larynge d'intubation en cas de spondylarthrite ankylosante severe]
Can J Anesth, November 1, 2001; 48(10): 1015 - 1019.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
K. Okuda, G. Inagawa, T. Miwa, and K. Hiroki
Influence of head and neck position on cuff position and oropharyngeal sealing pressure with the laryngeal mask airway in children
Br. J. Anaesth., January 1, 2001; 86(1): 122 - 124.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
A. J. Shysh
Adult learning principles: you can teach an old dog new tricks/On peut apprendre a tout age
Can J Anesth, September 1, 2000; 47(9): 837 - 842.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lu, P.-P.
Right arrow Articles by Shyr, M.-H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lu, P.-P.
Right arrow Articles by Shyr, M.-H.
Related Collections
Right arrow Cardiothoracic Anesthesia, Respiration and Airway


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the Canadian Anesthesiologists' Society.