CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shaaban Ali, M.
Right arrow Articles by Latto, I.P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shaaban Ali, M.
Right arrow Articles by Latto, I.P.
Canadian Journal of Anesthesia 48:497-501 (2001)
© Canadian Anesthesiologists' Society, 2001

Cardiothoracic Anesthesia, Respiration and Airway

Spatially resolved spectroscopy (NIRO-300) does not agree with jugular bulb oxygen saturation in patients undergoing warm bypass surgery

M. Shaaban Ali, MB BCH MSc, M. Harmer, MD FRCA, R.S. Vaughan, FRCA, J.A. Dunne, FRCA and I.P. Latto, FRCA

From the Department of Anaesthetics and Intensive Care Medicine, University of Wales College of Medicine, Heath Hospital, Heath Park, Cardiff, UK.

Address correspondence to: Dr. M. Shaaban Ali, Department of Anaesthesia, University of Wales College of Medicine, Cardiff CF14 4XN, UK. Phone: 0044-29-20-743110; Fax: 0044-29-20-747203; E mail: msali58{at}hotmail.com

Objectif : La spectroscopie proche infrarouge (SPIR) est une méthode non effractive et prometteuse de monitorage continu de l'oxygénation cérébrale utilisée en chirurgie cardiaque sous circulation extracorporelle (CEC). L'étude actuelle voulait tester la concordance entre l'index d'oxygène tissulaire (IOT) mesuré par spectroscopie à résolution spatiale (NIRO-300) et la saturation en oxygène du golfe de la jugulaire (SjO2) pendant une cardioplégie chaude.

Méthode : Dix sept patients subissant un pontage coronarien sous cardioplégie chaude ont été étudiés. La SPIR a été surveillée continûment et ajustée avant la CEC, à cinq, 20, 40, 60 min pendant la CEC, cinq minutes avant la fin de la CEC et dix minutes après pour coïncider avec les mesures moyennes de SjO2. La température a été maintenue à 34–37°C pendant la CEC.

Résultats : L'analyse de Bland et Altman a montré un biais (IOT–SjO2) de -6,7 % et de larges limites de concordance (de 16 % à -28 %) entre les deux méthodes. De plus, l'IOT moyen était plus bas que la SjO2 moyenne pendant et après la CEC. Il existait une corrélation statistiquement significative entre le gaz carbonique artériel et les mesures de SjO2(r2 = 0,33; P = 0,0003), mais non entre le CO2 et les valeurs de l'IOT (r2 = 0,001; P = 0,7).

Conclusion : Nos résultats démontrent un manque de concordance entre la SjO2 et l'IOT lors du monitorage de l'oxygénation cérébrale pendant une intervention cardiaque. Les deux méthodes ne sont donc pas interchangeables.




This article has been cited by other articles:


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
S. Chakravarti, S. Srivastava, and A. J. C. Mittnacht
Near Infrared Spectroscopy (NIRS) in Children
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2008; 12(1): 70 - 79.
[Abstract] [PDF]


Home page
StrokeHome page
P. G. Al-Rawi and P. J. Kirkpatrick
Tissue Oxygen Index: Thresholds for Cerebral Ischemia Using Near-Infrared Spectroscopy
Stroke, November 1, 2006; 37(11): 2720 - 2725.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
T. M. Hemmerling, J.-F. Olivier, F. Basile, N. Le, and I. Prieto
Bispectral Index as an Indicator of Cerebral Hypoperfusion During Off-Pump Coronary Artery Bypass Grafting
Anesth. Analg., February 1, 2005; 100(2): 354 - 356.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
M.-C. Taillefer and A. Y. Denault
Cerebral near-infrared spectroscopy in adult heart surgery: systematic review of its clinical efficacy: [La spectroscopie cerebrale par infrarouge en cardiochirurgie chez l'adulte : une etude systematique de son efficacite clinique]
Can J Anesth, January 1, 2005; 52(1): 79 - 87.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
N. Nagdyman, T. P. K. Fleck, P. Ewert, H. Abdul-Khaliq, M. Redlin, and P. E. Lange
Cerebral oxygenation measured by near-infrared spectroscopy during circulatory arrest and cardiopulmonary resuscitation
Br. J. Anaesth., September 1, 2003; 91(3): 438 - 442.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
G Naulaers, G Morren, S Van Huffel, P Casaer, and H Devlieger
Cerebral tissue oxygenation index in very premature infants
Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2002; 87(3): F189 - 192.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
M. Weiss, G. Schulz, M. Fasnacht, C. Balmer, J. E. Fischer, A. C. Gerber, H.-U. Bucher, and O. Baenziger
Transcutaneously measured near-infrared spectroscopic liver tissue oxygenation does not correlate with hepatic venous oxygenation in children: [La mesure transcutanee de l'oxygenation du tissu hepatique par spectroscopie proche infrarouge ne correspond pas a l'oxygenation hepatique veineuse chez les enfants]
Can J Anesth, October 1, 2002; 49(8): 824 - 829.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shaaban Ali, M.
Right arrow Articles by Latto, I.P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shaaban Ali, M.
Right arrow Articles by Latto, I.P.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the Canadian Anesthesiologists' Society.