CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frölich, M. A.
Right arrow Articles by Caton, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frölich, M. A.
Right arrow Articles by Caton, D.
Canadian Journal of Anesthesia 49:185-189 (2002)
© Canadian Anesthesiologists' Society, 2002

Obstetrical and Pediatric Anesthesia

Baseline heart rate may predict hypotension after spinal anesthesia in prehydrated obstetrical patients

[La fréquence cardiaque initiale peut être prédictive d'hypotension après la rachianesthésie chez des patientes obstétricales préhydratées]

Michael A. Frölich, MD DEAA* and Donald Caton, MD{dagger}

* From the Departments of Anesthesiology and
{dagger} Obstetrics and Gynecology, University of Florida College of Medicine, Gainesville, Florida, USA.

Address correspondence to: Dr. Michael Frölich, Department of Anesthesiology, P.O. Box 100254, Gainesville, FL 32610, USA. Phone: 352-846-0914; Fax: 352-392-6407; E-mail froelich{at}anest1.anest.ufl.edu

Objectif : Chez les femmes enceintes, l'hypotension est la plus fréquente complication de la rachianesthésie. Notre étude veut identifier les patientes à risque d'hypotension postsrachidienne en notant les signes vitaux d'avant et après la provocation orthostatique.

Méthode : Quarante femmes en bonne santé, devant subir une césarienne, ont participé à cet essai prospectif. La tension artérielle (TA) et la fréquence cardiaque (FC) ont été notées alors que la patiente est en décubitus latéral, puis en station debout. La TA a été enregistrée toutes les deux minutes pendant 30 min à la suite de l'administration rachidienne de bupivacaïne. De l'éphédrine a été donnée en fonction du degré d'hypotension observée. On a mis en corrélation les paramètres hémodynamiques et les besoins d'éphédrine (corrélation des rangs de Spearman).

Résultats : Une corrélation significative a été notée entre la FC de base et les besoins d'éphédrine (P = 0,005). Il n'y a pas eu de corrélation entre le degré des modifications orthostatiques de la TA et de la FC moyennes et l'hypotension postrachidienne.

Conclusion : La FC initiale peut être prédictive d'hypotension rachidienne en obstétrique. Une FC initiale élevée, pouvant exprimer un tonus sympathique plus important, peut être un paramètre prédictif intéressant d'hypotension postrachidienne.




This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
R. Preston
Challenges in obstetric anesthesia and analgesia
Can J Anesth, June 1, 2008; 55(6): 386 - 389.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
P. Foex
Unexplained preoperative tachycardia: is it an important issue?/Tachycardie preoperatoire inexpliquee : estce important ?
Can J Anesth, October 1, 2005; 52(8): 789 - 794.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
S. P. Cohen and C. Kent
Pronounced unexplained preoperative tachycardia heralding serious cardiac events: a series of three cases: [Tachycardie preoperatoire prononcee, inexpliquee, prodrome d'evenements cardiaques serieux : une serie de trois cas]
Can J Anesth, October 1, 2005; 52(8): 858 - 863.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
D. Chamchad, V. A. Arkoosh, J. C. Horrow, J. L. Buxbaum, I. Izrailtyan, L. Nakhamchik, D. Hoyer, and J. Y. Kresh
Using Heart Rate Variability to Stratify Risk of Obstetric Patients Undergoing Spinal Anesthesia
Anesth. Analg., December 1, 2004; 99(6): 1818 - 1821.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frölich, M. A.
Right arrow Articles by Caton, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frölich, M. A.
Right arrow Articles by Caton, D.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the Canadian Anesthesiologists' Society.