CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Monaca, E.
Right arrow Articles by Wappler, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Monaca, E.
Right arrow Articles by Wappler, F.
Canadian Journal of Anesthesia 52:801-804 (2005)
© Canadian Anesthesiologists' Society, 2005

General Anesthesia

Broken guide wire - a fault of design?

[Le bris d’un guide métallique - un défaut de conception ?]

Enrico Monaca, MD, Stefan Trojan, MD, John Lynch, MD, Manfred Doehn, MD and Frank Wappler, MD

From the University of Witten/Herdecke Department of Anesthesiology, Hospital Cologne-Merheim, Köln, Germany.

Address correspondence to: Dr. Enrico Monaca, Department of Anesthesiology, Hospital Cologne-Merheim, University Witten/Herdecke, Ostmerheimer Str. 200, D - 51109 Köln, Germany. Phone: 0049-221-8907-13196; Fax: 0049-221-8907-3868; E-mail: MonacaE{at}Kliniken-Koeln.de

Objectif : Présenter une complication potentiellement dangereuse du cathétérisme veineux central résultant d’un guide métallique défectueux.

Éléments cliniques : Le bris d’un guide métallique s’est produit chez un patient de 47 ans des soins intensifs. La pointe d’un guide en J est demeurée logée dans la veine jugulaire interne et la fluoroscopie a permis de la retirer, sans complication.

Conclusion : Le bris d’un guide métallique pendant l’insertion d’un cathéter veineux central a été très rarement rapporté. Mais des défauts de conception inhérents ou relevant du processus de fabrication peuvent mener à cette rare complication. Un simple test de chevet est proposé pour détecter le bris dans la partie centrale du guide métallique.




This article has been cited by other articles:


Home page
NEJMHome page
M. C. Reade, J. D. Newton, D. C. Sprigings, L. T. Newsome, B. L. Antonio, R. L. Royster, S. Adhya, S. K. Laha, A. S. Graham, K. Tegtmeyer, et al.
Central venous catheterization.
N. Engl. J. Med., August 30, 2007; 357(9): 943 - 944.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
K. Z. Khan, D. Graham, A. Ermenyi, and W. R. Pillay
Case report: Managing a knotted Seldinger wire in the subclavian vein during central venous cannulation: [Etude de cas : Extraction d'une broche guide de Seldinger nouee dans la veine sous-claviere pendant une canulation veineuse centrale]
Can J Anesth, May 1, 2007; 54(5): 375 - 379.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Monaca, E.
Right arrow Articles by Wappler, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Monaca, E.
Right arrow Articles by Wappler, F.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the Canadian Anesthesiologists' Society.