CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cooper, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cooper, R. M.
Canadian Journal of Anesthesia 54:54-57 (2007)
© Canadian Anesthesiologists' Society, 2007

Case Reports/Case Series

Complications associated with the use of the GlideScope® videolaryngoscope

[Complications suite à l’utilisation du vidéolaryngoscope GlideScope®]

Richard M. Cooper, MD

From the Department of Anesthesia, University of Toronto, Toronto General Hospital, Toronto, Ontario, Canada.

Address correspondence to: Dr. Richard M. Cooper, Department of Anesthesia, University of Toronto, Toronto General Hospital, 200 Elizabeth St., 3EN-421, Toronto, Ontario M5G 2C4, Canada. Phone: 416 340-5164; Fax: 416 340-3698; E-mail: richard.cooper{at}uhn.on.ca

Objectif : Sont présentés deux cas dans lesquels l’utilisation du vidéolaryngoscope GlideScope® (GVL) a facilité l’exposition laryngée et l’intubation endotrachéale, mais a eu pour conséquence un traumatisme pharyngé.

Eléments cliniques : La vidéolaryngoscopie avec le GlideScope® a été effectuée sur deux patientes chez qui on anticipait une laryngoscopie directe difficile. Dans le premier cas, suite à l’induction de l’anesthésie, une difficulté modérée a été rencontrée à orienter la sonde endotrachéale (SET) vers le larynx de la patiente. Dans le second cas, peu de difficultés ont été rencontrées avec le GVL, et aucun problème n’a été identifié lors de l’instrumentation des voies aériennes jusqu’à ce que les champs qui couvraient le visage de la patiente soient enlevés. Dans les deux cas, la SET avait traversé l’arche palato-pharyngée droite, nécessitant des points de suture chez la première patiente et une électrocautérisation chez la seconde.

Conclusion : Il n’existe pas d’articles déjà publiés rapportant des blessures suite à une laryngoscopie avec le GlideScope® ; toutefois, une perforation de l’arche palato-pharyngale, survenue chez deux patientes, illustre une complication rare du GVL, mais potentiellement importante. Nous présentons certaines stratégies pour diminuer la gravité de cette complication.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
M.-H. Tremblay, S. Williams, A. Robitaille, and P. Drolet
Poor Visualization During Direct Laryngoscopy and High Upper Lip Bite Test Score Are Predictors of Difficult Intubation with the GlideScope(R) Videolaryngoscope
Anesth. Analg., May 1, 2008; 106(5): 1495 - 1500.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
J. E. Cho and H. K. Kil
A maneuver to facilitate endotracheal intubation using the GlideScope(R)
Can J Anesth, January 1, 2008; 55(1): 56 - 57.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
T. P. Turkstra, C. C. Harle, K. P. Armstrong, P. M. Armstrong, R. A. Cherry, J. Hoogstra, and P. M. Jones
The GlideScope(R)-specific rigid stylet and standard malleable stylet are equally effective for GlideScope(R) use: [Le mandrin rigide specifique au GlideScope(R) et le mandrin flexible standard sont tous deux aussi efficaces pour l'utilisation avec le GlideScope(R)]
Can J Anesth, November 1, 2007; 54(11): 891 - 896.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
P. Cross, J. Cytryn, and K. K. Cheng
Perforation of the soft palate using the GlideScope(R) videolaryngoscope
Can J Anesth, July 1, 2007; 54(7): 588 - 589.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
M. K.F. Choo, V. S.T. Yeo, and J. J. See
Another complication associated with videolaryngoscopy
Can J Anesth, April 1, 2007; 54(4): 322 - 324.
[Full Text] [PDF]

eLetters:

Read all eLetters

Maintain Visual Contact
Davide Cattano, et al.
CJA Online, 19 Apr 2007 [Full text]

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cooper, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cooper, R. M.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the Canadian Anesthesiologists' Society.