CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pandey, C. K.
Right arrow Articles by Sikora, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pandey, C. K.
Right arrow Articles by Sikora, R.
Canadian Journal of Anesthesia 47:602 (2000)
© Canadian Anesthesiologists' Society, 2000


Correspondence

Egress of air through minitracheostomy tube: a dilemma about its position

Chandra Kant Pandey, MD, Devashish Chakravarty, MD PDCC, Namita Singh, MD PDCC and Rehana Sikora, MD

Lucknow, India

To the Editor:

Retention of tracheobronchial secretions is a frequent cause of morbidity in patients with neuromuscular disorders. The advantages of minitracheostomy over more traditional methods of dealing with sputum retention have been described.1,2 We report a complication of minitracheostomy which was otherwise unsuspected.

A 29-yr-old woman was referred with progressive muscle weakness in all limbs, difficulty in swallowing and breathing and ineffective cough and was diagnosed as Guillain Barré Syndrome based on nerve conduction studies. After tracheal intubation and pressure support ventilation, she showed rapid motor recovery but was unable to clear her respiratory secretions. Extubation and minitracheostomy were planned.

A16-gauge needle was introduced between 1st and 2nd tracheal rings, air aspirated and a guide wire passed, the latter requiring some force. The internal diameter tracheal cannula was then slid over the guide wire and fixed in position. The position was checked by aspirating air through the minitracheostomy tube and, with every breath, air moved freely in and out of the tube. However no secretions could be aspirated even after instilling saline. Chest X ray revealed the cannula tip in the right pleural space and right side pneumothorax with collapsed lung parenchyma (Figure). The cannula was removed and the patient was managed with a nasotracheal tube.

Chest X-ray usually confirms the proper position of tracheostomy. In cases where negotiation of the guide wire is not smooth, the absence of tracheal secretion should raise suspicion about the malposition of tracheostomy tube.



View larger version (120K):
[in this window]
[in a new window]
 
FIGURE -Position of minitracheostomy and right side pneumothorax in chest Ray AP view.

 
References

1 Matthews HR, Hopkinson RB. Treatment of sputum retention by minitracheotomy. Br J Surg 1984; 71: 147–50.[Medline]

2 Yeoh NTL, Wells FC, Goldstraw P. A complication of minitracheostomy. Br J Surg 1985; 72: 633.[Medline]





This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pandey, C. K.
Right arrow Articles by Sikora, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pandey, C. K.
Right arrow Articles by Sikora, R.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS