| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
From the Departments of Neurosurgery,
* Anesthesia and Pharmacology, Dalhousie University, Halifax, Nova Scotia, Canada.
Address correspondence to: Dr. Orlando Hung, Department of Anesthesia, Queen Elizabeth II Health Sciences Centre, Victoria General Site, 1278 Tower Road, Halifax, Nova Scotia, B3H 2Y9 Canada. Phone: 902-473-7767; Fax: 902-423-9454; E-mail: hungorla{at}is.dal.ca
| Abstract |
|---|
|
|
|---|
Methods: The desired puncture site was marked on the skin of the anterior neck. A lightwand (Trachlight) was inserted into the patient's endotracheal tube (ETT), so that the number indicator on the lightwand matched the number indicator of the ETT of the patient. At this position, the light bulb of the lightwand was exactly placed at the tip of the endotracheal tube. With the lightwand turned on, the lightwand together with the endotracheal tube (ETT-LW) was slowly withdrawn from the trachea until a bright glow in the anterior neck could be seen 1 cm above the marked puncture site. At this position, the tip of the ETT was 1 cm above the puncture site.
Results: Percutaneous tracheostomy via a light-guided tracheal puncture was performed on 11 neurosurgical patients. The withdrawal of the endotracheal tube to a location above the puncture was accomplished easily with the lightwand. All percutaneous tracheostomies performed were successful, with ease and without any complications.
The procedure time was 17.8 ± 5.3 min. Mechanical ventilation was not interrupted during the whole procedure.
Conclusion: The lightwand guided intratracheal puncture for percutaneous tracheostomy is a simple, effective, and safe procedure. This technique can avoid the risk of puncturing the endotracheal tube and/or cuff, thus allowing adequate ventilation and oxygenation during the percutaneous tracheostomy. Furthermore, this technique is inexpensive and minimizes the risk of damaging equipment like the fibreoptic bronchoscope.
| Introduction |
|---|
|
|
|---|
| Methods |
|---|
|
|
|---|
Ciaglia percutaneous tracheostomy kit (Cook Inc, Bloomington, IN 47402, USA) was used to perform the tracheostomy. All percutaneous tracheostomies were performed by the neurosurgeon (BMA), who had experience with both the percutaneous tracheotomy and the standard open tracheostomy prior to the study. A lightwand (TrachlightTM, Laerdal Medical Inc., Wappingers Falls, New York) was used for the transillumination of the neck soft tissues.15 The TrachlightTM consists of three parts: a reusable handle, a flexible wand, and a stiff retractable stylet. The retractable stylet is enclosed within the wand. The advantage of using the TrachlightTM over other commercially available lightwands was the pliability of the wand when the internal stylet was removed. In addition, while placing the lightwand into the ETT, the number indicators on the wand of the Trachlight can be positioned at the number indicators on the ETT. This usually requires the ETT to be cut to fit the lightwand. At this position, the light bulb of the Trachlight will be at the tip of the ETT. Transillumination using this setup allows the determination of the tip of the ETT during percutaneous puncture of the trachea.
Under sterile conditions, the desired percutaneous puncture site was identified and marked on the skin at the level of the interval between the first and the second tracheal rings or the space between the cricoid cartilage and the first ring (Figure
). Through a bronchoscopy connector (Portex Fiberoptic Bronchoscope Swivel Adaptor, SIMS Portex Inc., Keene, NH), the Trachlight without the internal stiff wire was inserted into the ETT of the patient such that ventilation and oxygenation could be maintained while withdrawing the ETT. The number indicator on the lightwand was positioned to match the number indicator of the ETT. This step involved cutting the ETT at 26 cm mark to fit the lightwand. The cuff of the ETT was deflated. With the lightwand turned on, the lightwand together with the endotracheal tube (ETT-LW) was slowly withdrawn from the trachea until a bright glow in the anterior neck from the transillumination of the lightwand could be seen 1 cm above the marked puncture site (Figure
). At this position, the tip of the ETT was 1 cm above the puncture site. It should be emphasized that the ETT must be secured properly at this position to prevent advancement or further withdrawal during the percutaneous tracheostomy procedure. With the tip of the ETT at this position, the cuff of the ETT was reinflated where mechanical ventilation could be easily provided while the tracheal puncture was made using a modified percutaneous tracheostomy technique as described by Ciaglial. The absence of air leak confirmed the balloon integrity. The skin and underlying tissue were infiltrated with lidocaine 2% with epinephrine (1:100,000) as a vasoconstrictor to minimize bleeding at the site of the incision. A 1 cm vertical was made halfway between the thyroid cartilage and the suprasternal notch. The soft tissue of the neck including the thyroid gland isthmus and the trachea were identified. With the isthmus of the thyroid gland pushing downward, the trachea was punctured between the second and third tracheal ring by a 16 gauge intravenous catheter attached to 5 ml syringe filled with Xylocaine 1%. Following the tracheal puncture, as confirmed by the aspiration of free air, the intravenous catheter was further advanced 0.5 cm to ensure that the plastic cannula was in the trachea. After the removal of the needle, l ml of lidocaine was injected into the trachea through the cannula. A flexible J guide wire was inserted through the cannula caudally 6-8 cm beyond the tip of the cannula. The intravenous cannula was then removed, leaving the guide wire in place. A #8 Fr Teflon catheter was then inserted over the guide wire. This was followed by the insertion of a series of dilators from #12 Fr to #36 Fr. Finally, a #8 Shiley tracheostomy tube fitted snugly over a well lubricated #28 Fr dilator was inserted over the guide wire. After the insertion of the tracheostomy tube, the proper placement was confirmed with end-tidal CO2.
|
| Results |
|---|
|
|
|---|
| Discussion |
|---|
|
|
|---|
Although this lightwand-guided percutaneous tracheostomy is a simple and effective technique, it has limitations. Since this is a relatively "blind" technique, it should be used with great caution in patients with coagulopathy when homeostasis should be controlled surgically using the conventional surgical technique. Furthermore, since this light-guided technique uses the principle of transillumination of the soft tissue of the neck, its use should be avoided in patients where transillumination would be difficult or impossible, for example, in patients who are grossly obese or who have a short or "thick neck".
In our opinion, the most difficult part of the procedure was the insertion of the tracheostomy tube into the trachea. In a few of the study patients, substantial resistance was encountered during the insertion. This could be due to the different shape of the dilator (round) and the lumen of the tracheostomy tube (oval). The small gap between the dilator and the tracheostomy tube considerably increased the resistance of the tracheostomy tube on entering the trachea. However, generous lubrication and a steady rotating pressure can overcome this resistance. A well lubricated #28 Fr dilator fitted snugly through the tracheostomy tube would ensure a smooth and easy advancement over the guide wire.
Since percutaneous tracheostomy is a simple technique and can be performed safely in the ICU, it can be a cost-effective alternative to the standard open tracheostomy. In a study with 183 patients, McHenry et al. had shown that percutaneous tracheostomy required considerably less time to perform compared to the standard open tracheostomy (21 ± 6 min for percutaneous tracheostomy vs 46 ± 21 min for open standard tracheostomy).16 Although in this study, we did not include a control group to evaluate the time required to perform the percutaneous tracheostomy, the time to perform the light-guided percutaneous tracheostomy was 17.8 ± 5.3 min. The time is slightly shorter than the time reported to perform the percutaneous tracheostomy by McHenry et al.
Although we did not use this light-guided technique for a conventional open tracheostomy, it is conceivable that this simple technique will also allow the accurate withdrawal of the tip of the ETT above the surgical tracheostomy site. Similarly, this lightwand-guided technique will likely minimize the risk of damaging the ETT or the cuff and allow adequate oxygenation and ventilation during the surgical tracheostomy.
In summary, in a small series of patients, we have demonstrated that a lightguided percutaneous tracheostomy using a lightwand is an effective and safe technique to withdraw the endotracheal tube accurately prior to tracheal puncture.
Accepted for publication June 14, 2000.
| References |
|---|
|
|
|---|
2 Toye FJ, Weinstein JD. Clinical experience with percutaneous tracheostomy and cricothyroidotomy in 100 patients. J Trauma 1986; 26: 103440.[Medline]
3 Hazard PB, Garrett HE Jr, Adams JW, Robbins ET, Aguillard RN. Bedside percutaneous tracheostomy: experience with 55 elective procedures. Ann Thorac Surg 1988; 46: 637.[Abstract]
4 Schachner A, Ovil Y, Sidi J, Rogev M, Heilbronn Y, Levy MJ. Percutaneous tracheostomy-a new method. Crit Care Med 1989; 17: 10526.[Medline]
5 Mphanza T, Jacobs S, Chavez M. A potential complication associated with percutaneous tracheostomy with an endotracheal tube with a murphy eye in situ (Letter). Anesthesiology 1998; 88: 1418.[Medline]
6 Schwann N. Percutaneous dilational tracheostomy: anesthetic considerations for a growing trend. Anesth Analg 1997; 84: 90711.[Medline]
7 Day C, Rankin N. Laceration of the cuff of an endotracheal tube during percutaneous dilational tracheostomy (Letter). Chest 1994; 105: 644.
8
Reilly PM, Anderson HL III, Sting RF, Schwab CW, Bartlett RH. An unrecognized phenomenon during percutaneous endoscopic tracheostomy. Chest 1995; 107: 17603.
9 Toursarkissian B, Zweng TN, Kearney PA, Pofahl WE, Johnson SB, Barker DE. Percutaneous dilational tracheostomy: report of 141 cases. Ann Thorac Surg 1994; 57: 8627.[Abstract]
10 Pignataro ED. Bronchoscopy-assisted bedside percutaneous tracheostomy. Int J Trauma Nurs 1998; 4: 236.[Medline]
11 Marelli D, Paul A, Manolidis S, et al. Endoscopic guided percutaneous tracheostomy: early results of a consecutive trial. J Trauma 1990; 30: 4335.[Medline]
12 Brimacombe J, Clarke G. Endoscopy in percutaneous tracheostomy (Letter). Br J Hosp Med 1994; 51: 496.
13 Fernandez L, Norwood S, Roettger R, Gass D, Wilkins H III. Bedside percutaneous tracheostomy with bronchoscopic guidance in critically ill patients. Arch Surg 1996; 131: 12932.[Abstract]
14 Barba CA, Angood PB, Kauder DR, et al. Bronchoscopic guidance makes percutaneous tracheostomy a safe, cost-effective, and easy-to-teach procedure. Surgery 1995; 118: 87983.[Medline]
15
Hung OR, Stewart RD. Lightwand Intubation: I. A new intubating device. Can J Anaesth 1995; 42: 8205.
16 McHenry CR, Raeburn CD, Lange RL, Priebe PP. Percutaneous tracheostomy: a cost-effective alternative to standard open tracheostomy. Am Surg 1997; 63: 64651.[Medline]
This article has been cited by other articles:
![]() |
F. Agro, F. Salvinelli, S. Gherardi, and M. Casale The lightwand: a useful aid in the difficult tracheostomy Can J Anesth, November 1, 2002; 49(9): 1000 - 1001. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |