| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |

* Form the Critical Care Division,
Maisonneuve Rosemont Hospital, Montréal, Québec Canada; and the Intensive Care Unit, CTO, CRF, ICORMA, Torino, Italy.
Dr. Yoanna Skrobik, Critical Care Division, Hôpital Maisonneuve-Rosemont, 5415, boul. de l'Assomption, Montréal, Québec H1T 2M4, Canada. Phone: 514-252-3400; Fax: 514-252-3806; E-mail: skrobiky{at}total.net
| Abstract |
|---|
|
|
|---|
Clinical features: Two cooperative COPD patients, who failed noninvasive mechanical ventilation, were intubated nasotracheally. Mechanical ventilation was initiated in pressure control mode via an uncuffed 6 mm tube.
Results: Respiratory rate improved after 1 hour (from 44 to 28 breathsmin1 in case 1 and from 32 to 25 breathsmin1 in case 2); PaC02 decreased (from 120 to 62 mmHg in case 1 and from 69 to 51 mmHg in case 2); with pressure control mode levels of 45 cm H2O and 55 cm H2O respectively. PaO2 increased from 40 mmHg (with FIO2 0.3) to 55 mmHg (with FIO2 0.3) in the first patient and from 55 mmHg (with FIO2 0.4) to 60 mmHg (with FIO2 0.4 ) in the second patient; pH improved from 7.18 to 7.31 in case 1 and from 7.22 to 7.39 in case 2. Patients were able to trigger the ventilator, speak, swallow and to clear secretions spontaneously. Both patients were ventilated for three days in this manner without any adverse effects. Both survived and were discharged home after 20 and 18 days in hospital respectively.
Conclusion: This very preliminary report suggests that, in carefully selected patients who fail mask ventilation, mechanical support with translaryngeal open ventilation can improve gas exchange, breathing pattern and tachypnea, without hindering glottic function.
| Introduction |
|---|
|
|
|---|
Transtracheal open ventilation has recently been described in COPD.79 Patients with acute respiratory failure who failed mask ventilation were randomized to either conventional mechanical ventilation through a cuffed orotracheal tube, or transtracheal open ventilation, defined as ventilatory support through an uncuffed mini-tracheostomy tube. Mechanical ventilation was delivered using a pressure control mode. Patients with transtracheal open ventilation maintained glottic function and were able to swallow, eat, and speak. They required far less sedation and had a dramatically decreased incidence of ventilator associated pneumonia.8
Performing a mini-tracheotomy is invasive and requires specific expertise. We hypothesized that attempting mechanical ventilation through a small size naso-tracheal tube used with a deflated cuff ("translaryngeal open ventilation") in COPD patients could provide adequate ventilatory support and be of benefit in terms of comfort and preserved glottic function. We wish to describe our initial experience with this technique.
| Clinical features |
|---|
|
|
|---|
His arterial blood gas analysis on admission (with nasal cannulae delivering 6 L of oxygen a minute) showed a pH of 7.23, PaCO2 of 95 mmHg, HCO3 of 34, PaO2 48 mmHg. Face mask ventilation was attempted but was not tolerated by the patient despite reassurance. With mild sedation (propofol infusion at 0.8 mgkg1hr1 ) his PaCO2 rose to 120 mmHg, Pa02 dropped to 40 and he became more acidemic (pH 7.18).
The patient was still able to communicate and expressed anxiety at being unable to speak with an endotracheal tube in place. He accepted a trial with a small uncuffed endotracheal tube with the understanding that the treatment was experimental, might not work and require subsequent conventional endotracheal intubation with a full sized cuffed tube.
A 6-mm ID (Mallinckrodt Co) orotracheal 280-mm long tube was inserted into the patient's nose and advanced blindly into the trachea after topical anesthesia. The cuff was inflated briefly to measure intrinsic positive end expiratory pressure (PEEP) while initiating mechanical ventilation in assisted pressure control mode with a standard ICU ventilator (Servo 300, Siemens Elema, Uppsala, Sweden). Static intrinsic PEEP was obtained with the patient as relaxed as possible. PEEP was set at 80% of the intrinsic PEEP (8 cm H2O).10 The cuff was then deflated and expiratory volume measured via the ventilator. The inspiratory pressure was set between 45 and 55 cm of H2O to ensure expiratory volumes in the 250300 mL range. The respiratory rate was set at 20 breathsmin1 and the inspiratory time set to maximize patient comfort at 0.8 sec. The patient was able to trigger the ventilator with spontaneous breaths when the flow trigger was set to the 0.5 Lsec1 cm H20 range, with no auto-cycling. Gas exchange improved after one hour, with PaO2 levels stabilizing between 55 and 68 mmHg with 30% FIO2, and PaCO2 decreasing to values ranging from 62 to 67 mmHg. pH rose from 7.18 to 7.31. The patient was ventilated in this manner, with daily adjustments for his PEEP to match his auto-peep level, for 72 hr. He was able to speak in brief sentences and was able to swallow well enough to allow for oral feeding (see audiovisual supplement at www.cja-jca.org). The attending physician adjusted his therapy, which included antibiotics, corticosteroids, and inhaled bronchodilators. The only sedation required was a small dose of benzodiazepine at night. He was evaluated daily for clinical evidence of sinusitis, which did not occur. PaCO2 slowly returned to his baseline level of 55 mmHg, and he was extubated on the third day. Over the next 48 hr he required intermittent face mask ventilation, and was then discharged to the ward and home after 20 days in the hospital. He requested that he never be subjected to standard orotracheal intubation again, having found this mode of ventilation much more comfortable.
Case 2
A (70-yr-old) severe COPD patients (FEV1 of 0.45 L) on home oxygen therapy was admitted to hospital with acute hypercapnic respiratory failure and symptoms of recent viral illness. His vital signs showed a heart rate of 112 beatsmin1, arterial blood pressure of 160/90 mmHg, and a respiratory rate of 38 breathsmin1. He was afebrile. His blood gases on admission on 2 L of oxygen via nasal cannulae revealed a pH of 7.32 PaCO2 of 60 mmHg, HCO3 of 31 and paO2 48 mmHg. Face mask ventilation (PSV 20 cm H20, PEEP 4 cm H20) was initiated. Blood gases did not improve after one hour due to mask intolerance (pH 7.33 PaC02 59 mmHg Pa02 50 mmHg), with O2 at 4 L delivered via nasal prongs. Nose mask ventilation also failed. His blood gases deteriorated further (pH 7.22, PaC02 69 mmHg Pa02 55 mmHg) with O2 delivered at 40% via a face mask for two hours. The patient was still able to communicate and refused to be intubated. He accepted a trial with a small endotracheal tube with the understanding the treatment was experimental .
A 6-mm ID (Rusch, Germany), 380 mm long tube was inserted, after topical anesthesia, into the patient's right nostril and advanced blindly into the trachea. The cuff was left deflated. The extrinsic PEEP was set at 4 cm H2O without self-triggering. The pressure trigger sensitivity was set at 0.5 cm H20. The patient was ventilated with a Siemens 300 ventilator (Siemens Elema, Uppsala, Sweden) in the assisted pressure control mode at a rate of 15 breathsmin1. The inspiratory pressure was set at 55 cm H2O with an inspiratory time of one second to ensure expiratory volumes measured by the ventilator in the 250300 mL range. Blood gases showed a marked improvement (pH 7.39, PaC02 51 mmHg P02 60 mmHg on FI02 0.4) after one hour. Respiratory rate decreased from 32 to 25 breathsmin1.
Within 24 hr PaC02 dropped to 45 mmHg with a pH of 7.44; Pa02 rose to 70 with the same FI02. Glottic function was not impaired (clinically) allowing the patient to speak and swallow well enough to allow for oral feeding as in the patient described above. Therapeutic interventions included antibiotics, corticosteroids and inhaled bronchodilators. The patient required only a small dose of haloperidol for sedation. He was evaluated daily for clinical evidence of sinusitis. He was extubated successfully after 80 hr. After extubation 24-hr nose mask ventilation was maintained for two days. Subsequently, only nocturnal nasal ventilation was required and he could be weaned from mechanical ventilation nine days after hospital admission.
| Discussion |
|---|
|
|
|---|
Noninvasive ventilation is usually carried out in pressure pre-set modes. Assisted pressure control ventilation was chosen rather than pressure support ventilation10 to avoid patient-ventilator dys-synchrony, because of the patient's inability to reach the flow threshold value due to air leaks.11 Proximal airway pressure was high during inspiration. Previous studies have shown that distal airway pressure does not rise, because of high endotracheal tube resistance.1216 During expiration high tube resistance may be of concern; here expiration occurred partly through the native airway, decreasing the resistance caused by the tube, ventilator expiratory valve and circuit.17 With translaryngeal open ventilation PEEP could be applied to decrease the work of breathing or improve triggering.18
The patients tolerated the technique well. The uncuffed 6-mm ID tube interfered little with speech. Glottic function also seemed preserved clinically. Patients could ingest food and liquid. We did not observe any evidence of aspiration. The patients were able to cough and clear secretions. Endoscopic or radiologic investigations were not performed to validate objectively our clinical observations. "Silent" aspiration, although unlikely given the patients' clinical behaviour and course, could not be excluded.
The objective of the present report was to present the feasibility of improving gas exchange with translaryngeal open ventilation in conscious patients with acute decompensation of chronic respiratory disease. The technique, described in only two COPD patients, might not be applicable to patients with other clinical presentations, such as acute lung injury. Our clinical observations with regard to the preservation of glottic function, patient comfort and ability to communicate suggest there may be advantages to this technique. The benefits may parallel those observed in mask ventilated patients.
| Conclusion |
|---|
|
|
|---|
Revision received September 10, 2001. Accepted for publication June 5, 2001.
| References |
|---|
|
|
|---|
2 Torres A, Aznar R, Gatell JM, et al. Incidence, risk, and prognosis factors of nosocomial pneumonia in mechanically ventilated patients. Am Rev Respir Dis 1990; 142: 5238.[Medline]
3
Nava S, Ambrosino N, Clini E, et al. Nonivansive mechanical ventilation in the weaning of patients with respiratory failure due to chronic obstructive pulmonary disease. A randomized, controlled trial. Ann Intern Med 1998; 128: 7218.
4 Stauffer JL. Complications of endotracheal intubation and tracheotomy. Respir Care 1999; 44: 82843.
5 Hill NS. Noninvasive ventilation routine therapy for community-acquired pneumonia? Not so fast! (Editorial). Intensive Care Med 2001; 27: 7979.[Medline]
6 Brochard L. What is really important to make noninvasive ventilation work. Crit Care Med 2000; 28: 213940.[Medline]
7 Gregoretti C, Foti G, Beltrame F, et al. Pressure control ventilation and mintracheotomy in treating severe flail chest trauma. Intensive Care Med 1995; 21: 10546.[Medline]
8 Gregoretti C, Navalesi P, Squadrone V, Gottfried SB. Transtracheal open ventilation to treat acute exacerbation in non-invasive ventilation (NIMV) failures. Am J Critical Care Med 1999; 159: 3 A15 (abstract).
9 Gregoretti C, Confalonieri M, Gottfried S, Turello M, Biolini P, Navalesi P. Effect of a new cuffless translaringeal ventilatory support in restricitve patients with acute on chronic respiratory failure. Am J Respir Crit Care Med 2000; 161: A384 (abstract).
10 Boysen PG, McGough E. Pressure-control and pressure-support ventilation: flow patterns, inspiratory time, and gas distribution. Respir Care 1988; 33: 12634.
11 Calderini E, Confalonieri M, Puccio PG, Francavilla N, Stella L, Gregoretti C. Patient-ventilator asynchrony during noninvasive ventilation: the role of expiratory trigger. Intensive Care Med 1999; 25: 6627.[Medline]
12
Bach JR, Alba AS. Tracheostomy ventilation. A study of efficacy with deflated cuffs and cuffless tubes. Chest 1990; 97: 67983.
13
Nomori H, Ishihara T. Pressure-controlled ventilation via a mini-tracheostomy tube for patients with neuromuscular disease. Neurology 2000; 55: 698702.
14 Watt JWH, Fraser MH. The effect of insufflation leaks upon ventilation. A quantified comparison of ventilators. Anaesthesia 1994; 49: 3203.[Medline]
15 Watt JWH, Fraser MH. The effect of insufflation leaks in long-term ventilation. Waking and sleeping transcutaneous gas tensions in ventilator-dependent patients with an uncuffed tracheostomy tube. Anaesthesia 1994; 49: 32830.[Medline]
16 van Lunteren E, Van de Graaff WB, Parker DM, et al. Nasal and laryngeal reflex responses to negative upper airway pressure. J Appl Physiol 1994; 56: 74675.
17 Banner MJ, Downs JB, Kirby RR, Smith RA, Boysen PG, Lampotang S. Effects of expiratory flow resistance on inspiratory work of breathing. Chest 1988; 93: 7959.[Abstract]
18 Petrof BJ, Legare M, Goldberg P, Milic-Emili J, Gottfried SB. Continuous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical ventilation in severe chronic obstructive pulmonary disease. Am Rev Respir Dis 1990; 141: 2819.[Medline]
This article has been cited by other articles:
![]() |
C. Gregoretti, V. Squadrone, C. Fogliati, C. Olivieri, and P. Navalesi Transtracheal Open Ventilation in Acute Respiratory Failure Secondary to Severe Chronic Obstructive Pulmonary Disease Exacerbation Am. J. Respir. Crit. Care Med., April 15, 2006; 173(8): 877 - 881. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Ferraro, A. Capasso, E. Troise, S. Lanza, G. Azan, F. Rispoli, and C. B. Anello Assessment of Ventilation During the Performance of Elective Endoscopic-Guided Percutaneous Tracheostomy: Clinical Evaluation of a New Method Chest, July 1, 2004; 126(1): 159 - 164. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |