Methods: A prospective, randomized double-blind clinical study was conducted in 120 female patients scheduled for elective gynecological laparotomy. A lumbar epidural catheter and an iv catheter placed in the cephalic vein of the non-dominant hand were used in all patients. Patients of the control group (Group C) were given epidural normal saline followed by iv normal saline then iv propofol. Patients of Group E were given epidural 2% lidocaine (0.08 mLcm1) followed by iv normal saline and then propofol. Patients of Group V were given epidural normal saline followed by iv 2% lidocaine (0.05 mLkg1) then propofol. Pain was scored as no pain=0, minimal pain=1, moderate pain=2, severe pain=3.
Results: The pain scores, in group E; 1 (02) and group V; 2 (02), were significantly lower than in group C; 2 (13); median (25th75th percentile) (P <0.001). There was no difference in pain score between groups E and V. The plasma lidocaine concentration 15 min after epidural lidocaine was 2.74 ± 0.54 µgmL1, compared with 1.54 ± 0.31 µgmL1 at three minutes after iv lidocaine.
Conclusion: Epidural and iv lidocaine equally reduced the severity of propofol injection pain despite higher lidocaine plasma concentrations in epidurally administered lidocaine.
| Introduction |
|---|
|
|
|---|
| Methods |
|---|
|
|
|---|
Following injection of a small dose (<2 mL) of procaine hydrochloride 1% for local anesthesia, the epidural space was punctured using the loss-of-resistance technique with normal saline at the L23 intervertebral space by a paramedian approach. An epidural catheter was inserted and its tip placed 45 cm cephalad.
An 18-gauge Teflon® cannula (Insyte-WTM VialonTM E, Becton Dickinson, NJ) was inserted into the cephalic vein of the non-dominant hand, without the use of local anesthetic, early in the morning (about three hours before the induction of anesthesia) in the ward on the day of surgery and iv infusion of lactate Ringer's solution was started.
For arterial pressure monitoring and blood sampling, a 20-gauge Teflon® cannula (Insyte-WTM VialonTM E, Becton Dickinson) was inserted into the radial artery on the forearm contralateral to the venous line, following injection of a minimal dose (<1 mL) of procaine hydrochloride 1% for local anesthesia.
Patients were randomly allocated into one of three groups (C, E and V). Normal saline (0.08 mLcm1 body height) was administered epidurally in patients of group C (control group, n=40), followed 12 min later by iv injection of normal saline (0.05 mLkg1). Three minutes later, propofol (2.5 mgkg1) was injected through the same (cephalic) vein used for injection of normal saline.
Lidocaine 2% (0.08 mLcm1) was administered epidurally in patients of group E (n=43). This was followed, 12 min later, by iv injection of normal saline, and three minutes later by injection of propofol at a dose similar to that used for group C. Analgesia in patients of group E was confirmed with the pinprick test 15 min after epidural administration of lidocaine.
Normal saline (0.08 mLcm1 body height) was injected epidurally in patients of group V (n=37). This was followed 12 min later by iv injection of 2% lidocaine (0.05 mLkg1), and three minutes later by propofol through the same vein as lidocaine.
Injection of lidocaine or normal saline into the epidural space was performed using a syringe pump (STC 525TM, Terumo, Japan) at a rate of 400 mLhr1. The dose of lidocaine was less than the recommended dose for ventricular arrhythmias and possible side-effects were explained in advance. Propofol was kept in an incubator set at 2023°C until just before administration. In the operating theatre, after setting conventional monitors and cannulating the radial artery, propofol was administered through a three-way stopcock directly connected to the cannula inserted into the cephalic vein, with the iv infusion line closed, using an electric-powered syringe pump (Graseby Anaesthesia Pump 3500TM, Graseby Medical, UK). The rate of injection was 3 mgkg1min1 and the total dose was 2.5 mgkg1.
The severity of pain during injection of propofol was rated using a four-point scale. It was considered to be too difficult for the patient to express the injection pain using complex terms within a short period during induction of anesthesia. Accordingly, before the administration of lidocaine, the patient was asked to evaluate pain during the injection of propofol and, when present, grade it as mild="grade 1", moderate="grade 2 ", or severe="grade 3", as used in previous reports.17 Absence of pain was scored as "grade 0". In each patient, the maximum degree of pain before falling asleep was recorded as the pain score. The time point when evaluating pain score was also recorded. In patients with pain score "0", "the time point" was recorded as 50 sec, representing the total period required for the injection of propofol.
Arterial blood samples were obtained at 30 sec, one, two, three, five, seven, ten, 15 and 30 min after epidural lidocaine and at 30 sec, one, two, three and five minutes after iv lidocaine, to determine the plasma lidocaine concentrations. Blood samples were collected from the arterial cannula.
After induction of anesthesia, the lungs were ventilated mechanically with 3050% oxygen in air through an endotracheal tube, in combination with epidural and continuous iv anesthesia using propofol. We administered epidural analgesia postoperatively with a combination of local anesthetics and opioids. The relationship between the pain score and the level of analgesia was analysed for group E. We also analysed the relationships between the pain score and plasma lidocaine concentrations at 15 min after epidural lidocaine, and those between pain score and plasma lidocaine concentrations at three minutes after iv lidocaine. Plasma lidocaine levels were measured using an automated analyser (TDXTM, ABBOTT, IL) with fluorescence polarization immunoassay.8 The detection range of lidocaine by this method is 0.110 µgmL1, according to the specifications provided by the manufacturer.
Data are reported as mean ± SD. Differences in age, body weight, body height and plasma lidocaine concentrations among the three groups were examined for statistical significance by using one-way analysis of variance (ANOVA). Differences in ASA status among groups was analysed with the chi-square test and those for pain score with the Kruskal-Wallis test followed by post-hoc Dunn's multiple comparison test (GraphPad PRISMTM version 3.02, GraphPad Software, San Diego, CA). The relationship between the pain score and time of pain evaluation, that between pain score and analgesic levels, and between pain score and plasma lidocaine concentrations were analysed with Spearman's correction coefficient by rank. The relationship between pain score and "time points" was analysed excluding patients with the pain score "0" because there were no patients in group C with pain score "0". P <0.05 was regarded as significant. DeltaGraph® 4.03J for WindowsTM (DeltaPoint®, Japan Polaroid Computing) was used for illustrations.
| Results |
|---|
|
|
|---|
|
|
|
|
|
|
| Discussion |
|---|
|
|
|---|
Among the various approaches used to reduce propofol injection pain is the use of lidocaine. Lidocaine is administered either mixed with propofol or prior to injection of propofol. There is some evidence to suggest that the analgesic effects of the former technique may be more effective than the latter.9,10 However, mixing of propofol emulsion with other drugs is not recommended by the manufacturer,11 because of possible changes in emulsion stability. Thus, the common practice of mixing lidocaine to propofol to reduce pain on injection should be considered carefully.11 Picard and Tramer12 used lidocaine (0.5 mgkg1) intravenously with a rubber tourniquet on the forearm 30 to 120 sec before propofol injection. They suggested that the "tourniquet method" is the most efficacious procedure to reduce propofol injection pain. Manger and Holak13 also demonstrated that application of a tourniquet inflated at a pressure of 50 mmHg followed by iv lidocaine (5 mL or 100 mg of lidocaine 2%) diminished hand pain associated with subsequent propofol injection. However, even though they reported the lack of any symptoms using this technique, it is possible that the rapid flow of 100 mg of lidocaine into the systemic circulation after the release of tourniquet might produce serious-side effects.
Picard and Tramer12 reviewed the results of using 15 different pharmaceutical agents by analysing 12 different physiological variables, in order to analyse the most appropriate techniques to reduce the incidence and severity of propofol injection pain. They concluded that injection of lidocaine/propofol and use of the tourniquet method were associated with the least pain. Several studies have examined the cause of propofol pain and the mechanisms of pain alleviation by various therapeutic techniques. Scott et al.9 suggested that propofol injection pain results from activation of the kinin cascade system and that lidocaine acts as a stabilizer of this system, preventing the release of pain-related mediators. When using the "tourniquet method", lidocaine held in the vein for a certain period of time results in anesthesia of the vein.13 Therefore, the efficacy of iv lidocaine should be higher with a tourniquet.
Propofol is presented in emulsion form due to its low water solubility. The emulsion droplets are less than 1 µm in diameter.11 Nathanson et al.5 demonstrated immediate changes in the stability of propofol emulsion when 1020 mg of lidocaine solution is added to 200 mg propofol. However, the changes in droplet size of propofol emulsion following the addition of <20 mg lidocaine to 200 mg propofol (final lidocaine concentration, 0.95%), are unlikely to be of clinical importance. An increase in the droplet size to >5 µm poses the risk of pulmonary fat embolism.14,15 In this regard, Ho and colleagues16 reported that the optimal concentration of lidocaine that reduced pain on injection of a propofol-lidocaine mixture was 0.1%. This concentration is within the acceptable range suggested by Nathanson et al.5 The mechanism explaining the efficacy of this technique we used remains unclear.11
Although iv lidocaine without a tourniquet prior to propofol injection, our results show that the analgesic effect of epidural lidocaine was not significantly different from that of iv bolus injection of lidocaine and the pain score after propofol injection was reduced to a similar level in both methods. The analgesic effects of epidural lidocaine on pain during injection of propofol might be explained by the following mechanisms: (a) a direct effect of epidural anesthesia; (b) the systemic effect of lidocaine following absorption from the epidural space. Furthermore, the effects of epidural lidocaine are likely to represent the central sedative effects of spinal deafferentation and involvement of the spinal cord in systemic analgesia. In our study, the level of analgesia did not exceed the level of T5, there were no signs of sympathetic nerve block in the upper extremities, and there was no significant relationship between the pain score and the level of analgesia. In group E, since lidocaine acted epidurally as well as systemically, the analgesic effect on pain during propofol injection should have been greater in these patients compared to those of group V. However, analysis of the pain scores showed no difference between the two groups.
In conclusion, the present study shows that lidocaine epidural anesthesia reduces pain during propofol injection. We also confirmed, in another group of patients, that pre-treatment with iv lidocaine reduces propofol-related pain. Both methods are useful to lessen propofol injection pain when the latter is used for the induction or maintenance of anesthesia. Our results also indicate that it is unnecessary to use iv lidocaine to prevent pain on injection of propofol when patients are scheduled to receive epidural lidocaine anesthesia. Further studies are necessary to investigate the pain reducing mechanism of epidural lidocaine.
| Acknowledgments |
|---|
| Footnotes |
|---|
Revision received March 4, 2001. Accepted for publication October 24, 2000.
| References |
|---|
|
|
|---|
2 Valtonen M, Iisalo E, Kanto J, Rosenberg P. Propofol as an induction agent in children: pain on injection and pharmacokinetics. Acta Anaesthesiol Scand 1989; 33: 1525.[Medline]
3 King SY, Davis FM, Wells JE, Murchison DJ, Pryor PJ. Lidocaine for the prevention of pain due to injection of propofol. Anesth Analg 1992; 74: 2469.[Abstract]
4 Lee TW, Loewenthal AE, Strachan JA, Todd BD. Pain during injection of propofol. The effect of prior administration of thiopentone. Anaesthesia 1994; 49: 8178.[Medline]
5 Nathanson MH, Gajraj NM, Russell JA. Prevention of pain on injection of propofol: a comparison of lidocaine with alfentanil. Anesth Analg 1996; 82: 46971.[Abstract]
6 Yokota S, Komatsu T, Komura Y, et al. Pretreatment with topical 60% lidocaine tape reduces pain on injection of propofol. Anesth Analg 1997; 85: 6724.[Abstract]
7
Iwama H, Nakane M, Ohmori S, et al. Nafamostat mesilate, a kallikrein inhibitor, prevents pain on injection with propofol. Br J Anaesth 1998; 81: 9634.
8 Caplan YH, Levine B. Application of the Abott TDx lidocaine, phenytoin, and phenobarbital assays to postmortem Blood Specimens. J Anal Toxicol 1988; 12: 2657.[Medline]
9 Scott RPF, Saunders DA, Norman J. Propofol: clinical strategies for preventing the pain of injection. Anaesthesia 1988; 43: 4924.[Medline]
10 Brooker J, Hull CJ, Stafford M. Effect lignocaine on pain caused by propofol injection (Letter). Anaesthesia 1985; 40: 912.
11 Lilley EMM, Isert PR, Carasso ML, Kennedy RA. The effect of the addition of lignocaine on propofol emulsion stability. Anaesthesia 1996; 51: 8158.[Medline]
12
Picard P, Tramer MR. Prevention of pain on injection with propofol: a quantitative systemic review. Anesth Analg 2000; 90: 9639.
13 Mangar D, Holak EJ. Tourniquet at 50 mm Hg followed by intravenous lidocaine diminishes hand pain associated with propofol injection. Anesth Analg 1992; 74: 2502.[Abstract]
14 Driscoll DF, Bhargava HN, Zaaim RH, Babayan VK, Bistrain BR. Physicochemical stability of total nutrient admixtures. Am J Health-Syst Pharm 1995; 15: 6234.
15 Lewis JS. Justification for use of 1.2 micron end-line filters on total nutrient admixtures. Hospital Pharmacy 1993; 28: 6568.
16 Ho C-M, Tsou M-Y, Sun M-S, Chu C-C, Lee T-Y. The optimal effective concentration of lidocaine to reduce pain on injection of propofol. J Clin Anesth 1999; 11: 296300.[Medline]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |