| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
From the Department of Anaesthesia, KK Women & Children's Hospital, Singapore.
Address correspondence to: Dr. Alex Tiong-Heng Sia, Department of Anaesthesia, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore 229 899. E-mail: athsia{at}kkh.com.sg
| Abstract |
|---|
|
|
|---|
Methods: Forty healthy parturients were randomly assigned into two groups to receive either intrathecal sufentanil 5 µg plus bupivacaine 1.25 mg (Group S) or intrathecal fentanyl 25 µg plus bupivacaine 1.25 mg (Group F). Apart from the duration of analgesia, pain scores and side effects were also evaluated.
Results: There was no significant difference in the duration of analgesia (mean 109 ± SD 49 min in Group F vs 118 ± 54 min in Group S, P=0.9). Group F had a more rapid onset of analgesia (P <0.05) and a higher cephalad block (median T4 vs T7, P <0.05) in the first 30 min after the block. No difference in the side effects was detected.
Conclusion: Fentanyl 25 µg is a good alternative to sufentanil 5 µg when added to bupivacaine 1.25 mg for early labour analgesia.
| Introduction |
|---|
|
|
|---|
The current study was primarily aimed at comparing the duration of analgesia of the commonly used dose of 25 µg for fentanyl with sufentanil 5 µg when added to intrathecal bupivacaine 1.25 mg for analgesia in early labour. If fentanyl 25 µg provides the same duration and quality of analgesia as sufentanil 5 µg when added to intrathecal bupivacaine 1.25 mg, then the routine use of sufentanil in this regard should be reexamined because of the vast cost difference between the two opioids. In this country, a vial of 50 µg sufentanil costs $5.00 US vs $0.30 US for a vial of 100 µg of fentanyl.
| Methods |
|---|
|
|
|---|
On request for analgesia, the parturients were given 500 ml of compound sodium lactate solution. The procedure was performed at either the L2/3 or L3/4 interspace, with the parturient in the sitting position. The DurasafeTM combined spinal/epidural anesthesia tray (Becton Dickinson, Franklin Lakes, NJ, USA) was used in all subjects. The epidural space was located with a 17G Weiss epidural needle via a loss-of-resistance to saline technique. A 27G high flow variable extension Whitacre needle was then inserted (with its orifice in the cephalad direction) into the subarachnoid space. The free flow of cerebral spinal fluid (CSF) was confirmed by aspirating about 0.1 ml of CSF into the syringe and observing the resultant bisfringens effect. The test solution was then injected over a 30-sec period with the help of a stop clock. The spinal needle was then removed and a 19G closed-end multiple-orifice epidural catheter inserted into the epidural space. The catheter was aspirated to exclude intravascular placement before it was secured to the skin. Nothing was administered through this catheter until the first request for analgesia. The parturients were subsequently positioned supine with a 15° left lateral tilt.
Visual analog pain scores ranging from 0 for no pain to 100 for worst pain imaginable were assessed prior to intervention and at times five, 15 and 30 min after intrathecal injection. The level of sensory blockade (to ice) and presence of motor blockade was assessed at similar intervals. Motor block was graded as 0=no difficulty with straight leg raises; 1=unable to flex hip, but able to flex knee; 2=unable to flex hip or knee, but able to flex ankle; 3=no movement against gravity in all leg joints. The presence of sedation, pruritis, shivering and nausea was also assessed. Sedation was graded as 0=none; 1=easily arousable by light touch, normal speech; 2=arousable with loud speech and shaking; 3=arousable with painful stimulation; 4=unarousable by any means. The other side effects were noted as absent or present. Blood pressure readings were taken prior to intervention and at five-minute intervals after intrathecal injection for the first 30 min. Hypotension was defined as systolic blood pressure under 90 mmHg, and was treated with 5 mg boluses of ephedrine. The variability of cardiotocographic readings was also assessed during this initial 30-min period. Any changes that required obstetric intervention in terms of drug therapy (terbutaline or nitroglycerine) or emergency Cesarean section was regarded as non-reassuring fetal status. These excluded type I decelerations or variable decelerations that resolved spontaneously after lying the parturient in the full left lateral position. Respiratory depression in terms of respiratory rate slower than eight breathsmin1 or shallow respiratory efforts was also assessed during this period.
The duration of analgesia was defined as the time interval from intrathecal injection to time of first request for more analgesia. The subjects in whom we failed to obtain clear CSF flow from the spinal needle (after two attempts) were classified as technical failures. They were withdrawn from the study. The envelopes were resealed and reassigned randomly to another parturient. The subjects in whom adequate analgesia was not achieved within 15 min of intrathecal injection were treated as analgesic failures, and 3 ml boluses of local anesthetic (0.2% ropivacaine) injected through the epidural catheter to produce pain relief. Data collected from these subjects in the first 15 min were included in our statistical analysis, and their numbers were not re-assigned. With the exception of duration of analgesia, data from parturients who delivered prior to requesting further analgesia were also included.
For statistical analysis, the unpaired Student's t test was used to compare duration of analgesia, the primary aim of our study. Other continuous data (age, height, weight, lowest blood pressure) were also analysed by using the t test. The Mann-Whitney U test was used to assess sensory levels, cervical dilatation and station. Serial pain scores were analysed by the analysis of variance (ANOVA) for repeated measure and posthoc application of Bonferroni's test. Fisher's exact test was used to compare the incidence of hypotension, nausea, shivering, sedation, non-reassuring fetal status, presence of motor block and use of oxytocin.
The sample size was computed to detect a difference in duration of analgesia of 30 min between the two groups (
=0.05, ß=0.2) based on the findings of our previous study.4
| Results |
|---|
|
|
|---|
There were no demographic differences between the two groups in terms of age, weight, height, cervical dilation or station at the time of intrathecal injection (Table I
).
|
|
|
|
|
| Discussion |
|---|
|
|
|---|
We found the onset of analgesia faster in the fentanyl group compared with sufentanil. This was also associated with a higher level of sensory block during the first 30 min in the fentanyl group. This could be partially explained by the argument that the fentanyl group was relatively overdosed compared with the sufentanil group. There is indirect evidence to suggest that our dosage ratio of 5:1 (fentanyl: sufentanil) was higher than the potency ratio of 3.2: 1 (f:s) for ED50 values (without the addition of any local anesthetic agent) from two separate studies.6,7 However, the validity of extrapolating the potency ratio, as measured by the ED50 for an arbitrary period of analgesia, to the current situation is debatable. Nevertheless, our previous study also showed that doubling the dose of intrathecal sufentanil plus bupivacaine produced a faster and higher cephalad block.4
Surprisingly, Palmer et al. noticed a slower onset of block in parturients who had received intrathecal sufentanil compared with fentanyl, in spite of the relatively higher doses of sufentanil injected.6,8 We could not ascertain whether the effect of a lower specific gravity of the fentanyl containing solution (relative to Group S, as inferred from the study by Richardson et al.) played a role in our observation of a faster and higher block in Group F.9 The blocks were performed in the sitting position and the density differences of that order have been shown to profoundly affect drug movement in a spinal canal model. 9A relatively faster rate of drug elimination and block regression in Group F could account for the lack of clinical difference in terms of the duration of analgesia between the two groups despite the higher block in Group F. By varying baricity, a relatively higher rate of block regression has also been shown with a greater spread of intrathecal bupivacaine although the extension of this relationship to our current protocol needs further evaluation.10
Our study shows that both regimens are probably safe for the mother and the fetus, although admittedly, our sample size was small. Only one subject in Group F developed clinically demonstrable unilateral weakness in her hip flexor during the 30- min period. None of the other subjects had any demonstrable motor blockade. The other side effects were either self-limited (pruritus) or clinically insignificant (hypotension).
In conclusion, both sufentanil 5 µg and fentanyl 25 µg were effective for analgesia in early labour when administered by intrathecal injection with bupivacaine 1.25 mg. Although fentanyl plus bupivacaine produced a faster onset than sufentanil plus bupivacaine, there was no difference in the duration of analgesia between the two groups. The great cost difference between fentanyl and sufentanil behooves that the combination of intrathecal fentanyl 25 µg plus bupivacaine 1.25 mg be considered as an alternative to sufentanil 5 µg plus bupivacaine 1.25 mg for the induction of analgesia in early labour.
Accepted for publication January 29, 2001.
| References |
|---|
|
|
|---|
2 Campbell DC, Camann WR, Datta S. The addition of bupivacaine to intrathecal sufentanil for labor analgesia. Anesth Analg 1995; 81: 3059.[Abstract]
3
Lee BB, Ngan Kee WD, Hung VYS, Wong ELY. Combined spinal-epidural analgesia in labour: comparison of two doses of intrathecal bupivacaine with fentanyl. Br J Anaesth 1999; 83: 86871.
4
Sia ATH, Chong JL, Chiu JW. Combination of intrathecal sufentanil 10 µg plus bupivacaine 2.5 mg for labor analgesia: is half the dose enough? Anesth Analg 1999; 88: 3626.
5
Douglas MJ. Walking epidural analgesia in labour (Editorial). Can J Anaesth 1998; 45: 60711.
6 Palmer CM, Cork RC, Hays R, Van Maren G, Alves D. The dose-response relation of intrathecal fentanyl for labor analgesia. Anesthesiology 1998; 88: 35561.[Medline]
7 Nelson KE, D'Angelo R, Foss ML, Meister GC, Hood DD, Eisenach JC. Intrathecal neostigmine and sufentanil for early labour analgesia. Anesthesiology 1999; 91: 12938.[Medline]
8 Herman NL, Calicott R, Van Decar TK, Conlin G, Tilton J. Determination of the dose-response relationship for intrathecal sufentanil in laboring patients. Anesth Analg 1997; 84: 125661.[Abstract]
9 Richardson MG, Wissler RN. Densities of dextrose-free intrathecal local anesthetics, opioids, and combinations measured at 37C. Anesth Analg 1997; 84: 959.[Abstract]
10 Kooger Infante NE, Van Gessel E, Forster A, Gamulin Z. Extent of hyperbaric spinal anesthesia influences the duration of spinal block. Anesthesiology 2000; 92: 131923.[Medline]
This article has been cited by other articles:
![]() |
C. White, J. Hardy, A. Boyd, and A. Hall Letter to the editor: Subcutaneous sufentanil for palliative care patients in a hospital setting Palliative Medicine, January 1, 2008; 22(1): 89 - 90. [PDF] |
||||
![]() |
W. Gogarten, H. Buerkle, H. Van Aken, A. T.H. Sia, C. J. Cheng, E. H. Lim, G. P. Loke, and H. M. Tan Cost containment in obstetric analgesia Can J Anesth, January 1, 2002; 49(1): 107 - 108. [Full Text] [PDF] |
||||
![]() |
V. B. Gunka and M. J. Douglas CSE for labour: the debate goes on ... / L'analgesie RPC pendant le travail : le debat se poursuit... Can J Anesth, June 1, 2001; 48(6): 519 - 521. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |