| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |



* From the Department of Anesthesiology, The Department Of Otorhinolaryngology, Ophthalmology and Head and Neck Surgery,
the Department Of Morphology Of The Institute Of Bioscience
of The School Of Medicine Of The University Of São Paulo (unesp), Bottucatu, São Paulo; and The Department Of Pathology,
School of Medicine of the University Federal of Triângulo Mineiro, Uberaba, Minas Gerais, Brazil.
Address correspondence to: Dr. Tânia Mara Vilela Abud, Departamento de Anestesiologia, Faculdade de Medicina, UNESP, Distrito de Rubião Junior, Botucatu (SP), Brazil, ZIP CODE 18.618-970. Phone: 55 14 6802-6222; Fax 55 14 6822-4026; E-mail: anestesi{at}fmb.unesp.br
| Abstract |
|---|
|
|
|---|
Methods: Sixteen mongrel dogs were randomly allocated to two groups: G1 (intracuff volume, 30 mL; n=8) breathed a mixture of O2 (l Lmin1) and air (l Lmin1) and G2 (intracuff volume, 30 mL; n=8) a mixture of O2 (l Lmin1) and N2O (l Lmin1). Anesthesia was induced and maintained with pentobarbitone. LMA cuff pressure was measured at zero (control), 30, 60, 90 and 120 min after #4 LMA insertion. The dogs were sacrificed, and biopsy specimens from seven predetermined areas of the pharynx in contact with the LMA cuff were collected for light (LM) and scanning electron microscopic (SEM) examination by a blinded observer.
Results: LMA intracuff pressure decreased with time in G1 (P <0.001) and increased in G2 (P <0.001). There was a significant difference between the groups (P <0.001). In both groups, the LM study showed a normal epithelium covering the pharyngeal mucosa and mild congestion in the subepithelial layer. There were no differences between the groups (P >0.10) or among the areas sampled (P >0.05). In both groups, the SEM study showed a normal pharyngeal mucosa with mild superficial desquamation. Few specimens in G1 and G2 showed more intense epithelial desquamation.
Conclusion: High LMA intracuff pressures produced by N2O do not increase pharyngeal mucosal injury in dogs.
| Introduction |
|---|
|
|
|---|
The cuff of the LMA is manufactured from silicone-based rubber, a substance which is known to rapidly absorb nitrous oxide (N2O). During general anesthesia, N2O diffuses into the air-filled LMA cuff more rapidly than air can diffuse out of it, giving rise to an increase in cuff volume and pressure.1 There are a few case reports in the literature about nerve palsy and arterial compression after LMA use during anesthesia with nitrous oxide.25 The potential role of intracuff N2O diffusion has been discussed in these cases.
There is no clear correlation between LMA intracuff pressure and pressure on the pharynx. LMA cuff inflation with the recommended injection volume6 results in the residual volume of the cuff being exceeded and, in turn, likely to generate pressures exceeding the pharyngeal mucosal capillary perfusion pressure (32 mmHg).7 Although pressures on the mucosa with the LMA are generally lower than 32 mmHg, they can exceed this value in some locations at higher cuff volumes.8,9
The aim of the study was to investigate, by light microscopy (LM) and scanning electron microscopy (SEM), the effects of high LMA intracuff pressures secondary to the use of N2O on the pharyngeal mucosa in dogs.
| Materials and methods |
|---|
|
|
|---|
Before anesthesia, an aneroid manometer (Tajiri Instrumental Co, Tokyo, Japan) was connected to a three-way stopcock to measure LMA intracuff pressure. Before each experiment, the device was calibrated against a mercury column. A three-way stopcock was connected to the LMA cuff pilot tube and opened to air so that intracuff pressure was at atmospheric pressure. A 50-mL syringe was connected to the third port, and air in the cuff was completely evacuated as for insertion by the method described in man.6
After a 12-hr fast, a 20-gauge (G) catheter was placed in the cephalic vein of each dog, anesthesia induced by a bolus injection of 25 mgkg1 of pentobarbitone, and maintained by an iv infusion of 3 mgkg1hr1, using an infusion pump (Anne, Abbott, Chicago, USA). The LMA was inserted by the same anesthesiologist, according to a technique adapted from that previously reported in humans.6 Each dog was placed in the dorsal decubitus, head extended, and the tongue pulled forward. The LMA was inserted, with the dorsal side firmly supported against the hard palate until resistance was felt. The cuff was inflated with 30 mL of air and the cuff pressure was measured with the LMA in place. Correct positioning was verified in all cases using a 12 cm H2O inspiratory pressure and the LMA adjusted until no air leak was observed without altering the intracuff pressure, and also by comparing inspired and expired tidal volumes. The LMA was then fixed to the mandible of the animal using a string.
The animals breathed spontaneously via a circle rebreathing system with absorption of carbon dioxide. Dogs were randomly (by opening a sealed envelope) allocated to two groups: G1 (n=8) breathed a mixture of 1 Lmin1 of air and 1 Lmin1 of oxygen and G2 (n=8) a mixture of 1 Lmin1 of oxygen and 1 Lmin1 of N2O.
Subsequently, a 20-G catheter was placed in the right femoral artery for blood pressure measurement (AS 3, Datex - Engstrom, Helsinki, Finland). An 18-G catheter was placed in the right jugular vein for infusion of 5 mLkg1hr1 of lactated Ringer's solution. Pulse rate and arterial oxygen saturation were measured by pulse oximetry using a sensor placed on the tongue (4700 Oxicap, Ohmeda, Louisville, USA). The end-tidal carbon dioxide, respiratory rate and inspired fractions of oxygen and N2O were measured with a sidestream gas analyser (4700 Oxicap, Ohmeda, Louisville, USA). The sampling port was located between the proximal end of the LMA and the Y-piece of the anesthetic breathing system. Tidal volume was measured using a Mark 8 Wright respirometer (Ferraris, London, England) placed in the expiratory limb of the breathing system.
Anesthesia was maintained for two hours, and measurement of intracuff pressures was performed immediately after insertion of the LMA and 30, 60, 90 and 120 min thereafter.
At the end of the experiment, the dogs were sacrificed with an excessive dose of iv pentobarbitone. The pharynx was removed with the LMA still in place, and biopsies of the mucosa taken from seven areas in contact with the LMA: hypopharynx (right and left side), piriform sinus (right and left side), arytenoid cartilage (right and left side), and cricoid cartilage. For SEM study, the specimens were fixed in 2.5% glutaraldehyde in a 0.1 M sodium phosphate buffer solution (pH 7.3) for at least 24 hr. They were post-fixed in 2% osmium tetroxide solution in the same buffer for one hour and dehydrated in a graded concentration of ethanol. The samples were dried in a critical point apparatus using liquid carbon dioxide, mounted on a metal stub, sputter coated with gold and examined in a scanning electron microscope (Philips, Holland). For LM study the specimens were fixed in 10% formalin solution for at least 48 hr, included in paraffin, cut and stained with hematoxylin eosin (H&E).
All LM and SEM evaluation were carried out by a single pathologist blinded to the treatment group. In the LM analysis the following characteristics were evaluated: epithelial surface (erosion and neutrophilic inflammatory infiltration) and subepithelial layer (congestion, hemorrhage, and neutrophilic inflammatory infiltration). The analysis was semiquantitative with scoring from 0 to 3 (without, mild, moderate, or severe injury, respectively). The extent of epithelial erosion was scored from 0 to 3 (0=no erosion; 1=1% to 30%; 2=31% to 60%; 3=61% to 100% of the area eroded). The pharynx from three dogs euthanized with an excessive dose of iv pentobarbitone and without having been subjected to ventilation with a LMA were used as controls (G0 Group) for SEM evaluation.
A Student t test was used for statistical comparison of the weight of the animals. Continuous data were compared using analysis of variance (ANOVA) for repeated measures followed by Tukey's test, in order to investigate differences over time. LM scores from each biopsy area were compared using the Mann-Whitney non parametric test for two independent samples. Comparisons between scores within each group were performed using the nonparametric test of Friedman, for dependent samples. A descriptive analysis was used for the SEM results. Data are reported as mean ± SD, and score results are presented as median (min-max). Probability levels less than 0.05 were considered significant.
| Results |
|---|
|
|
|---|
There was no difference in the mean weight of the dogs between the two groups: G1 (16.9 ± 3.7 kg) and G2 (18.4 ± 1.4 kg) (P > 0.10).
LMA intracuff pressure decreased with time in G1 (P <0.001), and it increased in G2 (P <0.001). A significant difference between intracuff pressures become apparent with time (P < 0.001) (Figure 1
).
|
|
|
| Discussion |
|---|
|
|
|---|
During administration of N2O, LMA cuff pressures increased, as expected. Previous studies have shown that LMA intracuff pressure increases steadily during anesthesia with N2O and may reach 200 mmHg or more on removal of the mask.1,7 These results show the importance of the rapid diffusion of N2O into the air-filled cuff. Control of the LMA cuff pressure should be performed, if not continuously, at least intermittently during anesthesia. Eventually, the large intracuff pressure generated with the LMA in place would increase the partial pressure of N2O within the cuff, decreasing the pressure gradient across the cuff wall, thereby limiting further diffusion.7,14 This can explain the stabilization of cuff pressures between times 60 and 120 min, as compared to time 30 min (Figure 1
).
Theoretically, the pressure exerted by the LMA cuff on the pharyngeal wall, may exceed the perfusion pressure of the pharyngeal mucosa.7,11,12 In recent studies in humans, pharyngeal mucosal pressures were recorded by microchip sensors at several sites on the LMA cuff. Mucosal pressures were generally much lower than those considered safe for the pharyngeal mucosa (40 cm H2O). The exerted pressure did not, in fact, distribute evenly on the pharynx, and the pressure exerted by the proximal part of the cuff was considerably higher.8,9,15 Nevertheless, direct measurement indicates that the pressure exerted on the mucosa generally increases with increasing cuff volumes.8,9
The upper airway anatomy of a dog is not the same as that of a humans, but the histological structure of the pharyngeal tissues is similar.16 The laryngopharyngeal mucosa is covered by a stratified squamous epithelium composed of several layers of flattened cells undergoing constant proliferation, maturation, and loss. This ephithelium is much more resistant to injuries than the ciliated pseudostratified respiratory epithelium which covers the trachea. We surmise that absence of major pharyngeal injuries in this study is related to the resilent nature of this epithelium combined with the mechanical properties of the pharynx, which is well adapted to large physiological pressure and volume changes, and the short duration of the study (two hours). We are unaware of histological studies with the LMA in situ for a longer period.
Studies in humans have shown that the position of the LMA is not always ideal, even when function is good.17 Sub-optimal positioning could result in compression of the pharyngeal tissues against rigid structures, such as the hyoid bone or cervical column, explaining the lingual, hypoglossal, or recurrent laryngeal nerve palsy and compression of the lingual artery sometimes seen after use of the LMA, during anesthesia with N2O.25 The potential role of high intracuff pressures, produced by overinflation of the cuff or intracuff N2O diffusion, was discussed in these cases but pressures had not been measured. Brain pointed out that the published inflation values represent maximum volumes and recommended not inflating the LMA cuff above a pressure of 60 cm H2O, in order to diminish the possibility of nervous or arterial compression.18
Studies have investigated whether the removal of gas from the LMA cuff changes the incidence of pharyngeal complaints after surgery.1922 In the majority of these studies, removal of gas from the LMA cuff to the minimum level required for an effective pressure (60 cm H2O) decreased the incidence of sore throat after surgery.1921 In contrast, in another study, the differences in LMA cuff pressures did not influence either the incidence or the severity of laryngopharyngeal complaints.22
In our study, factors other than intracuff pressure that might have influenced the development of pharyngeal mucosal alterations were excluded. Animals were maintained normotensive throughout the study. The same LMA was used in all cases and was inserted by a single experienced investigator. Lubrificants were not used to facilitate insertion. Anesthetic depth during insertion was adequate in all dogs to provide smooth placement of the LMA. Correct location of the LMA is easier in the dog than in humans, since the angle between the mouth and the oropharyngeal cavity is smaller and the mouth opens more than in humans.
In conclusion, high LMA intracuff pressures produced by N2O do not increase pharyngeal mucosal injury in dogs.
|
| Acknowledgments |
|---|
Revision received May 9, 2001. Accepted for publication March 2, 2001.
| References |
|---|
|
|
|---|
2 Laxton CH. Lingual nerve paralysis following the use of the laryngeal mask airway. Anaesthesia 1996; 51: 86970.[Medline]
3 King C, Street MK. Twelfth cranial nerve paralysis following use of a laryngeal mask airway. Anaesthesia 1994; 49: 7867.[Medline]
4 Cros AM, Pitti R, Conil C, Giraud D, Verhulst J. Severe dysphonia after use of a laryngeal mask airway. Anesthesiology 1997; 86: 498500.[Medline]
5 Wynn JM, Jones KL. Tongue cyanosis after laryngeal mask airway insertion (Letter). Anesthesiology 1994; 80: 14034.[Medline]
6
Brain AIJ. The laryngeal mask a new concept in airway management. Br J Anaesth 1983; 55: 8014.
7
Marjot R. Pressure excerted by the laryngeal mask airway cuff upon the pharyngeal mucosa. Br J Anaesth 1993; 70: 259.
8
Brimacombe J, Keller C. A comparison of pharyngeal mucosal pressure and airway sealing pressure with the laryngeal mask airway in anesthetized adult patients. Anesth Analg 1998; 87: 137982.
9 Keller C, Brimacombe J. Pharyngeal mucosal pressures, airway sealing pressures, and fiberoptic position with the intubating versus the standard laryngeal mask airway. Anesthesiology 1999; 90: 10016.[Medline]
10 Braz JRC, Martins RHG, Mori AR, Luna SPL. Investigation into the use of laryngeal mask airway in pentobarbital anesthetized dogs. Vet Surg 1999; 28: 5025.[Medline]
11
Asai T, Howell TK, Koga K, Morris S. Appropriate size and inflation of the laryngeal mask airway. Br J Anaesth 1998; 80: 4704.
12 O'Kelly SW, Heath KJ, Lawes EG. A study of laryngeal mask inflation. Pressures exerted on the pharynx. Anaesthesia 1993; 48: 10758.[Medline]
13
Brimacombe J, Berry A. Laryngeal mask airway cuff pressure and position during anaesthesia lasting one to two hours. Can J Anaesth 1994; 41: 58993.
14 Stanley TH. Nitrous oxide and pressures and volumes of high- and low-pressure endotracheal-tube cuffs in intubated patients. Anesthesiology 1975; 42: 63740.[Medline]
15
Keller C, Brimacombe J, Benzer A. Calculated versus measured pharyngeal mucosal pressures with the laryngeal mask airway during cuff inflation: assessment of four locations. Br J Anaesth 1999; 82: 399401.
16 Watanabe I. Scanning Electron Microscopy Atlas of Cells and Tissues of the Oral Cavity, 1st ed., São Paulo: FAPESP-CNPQ Publishers, 1998.
17
Keller C, Pühringer F, Brimacombe JR. Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway. Br J Anaesth 1998; 81: 1867.
18 Brain AIJ. Pressure in laryngeal mask airway cuffs (Letter). Anaesthesia 1996; 51: 603.
19 Burgard G, Möllhoff T, Prien T. The effect of laryngeal mask cuff pressure on postoperative sore throat incidence. J Clin Anesth 1996; 8: 198201.[Medline]
20 Nott MR, Noble PD, Parmar M. Reducing the incidence of sore throat with the laryngeal mask airway. Eur J Anaesthesiol 1998; 15: 1537.[Medline]
21 Brimacombe J, Holyoake J, Keller C, et al. Emergence characteristics and postoperative laryngopharyngeal morbidity with the laryngeal mask airway: a comparison of high versus low initial cuff volume. Anaesthesia 2000; 55: 33843.[Medline]
22 Rieger A, Brunne B, Striebel HW. Intracuff pressures do not predict laryngopharyngeal discomfort after use of the laryngeal mask airway. Anesthesiology 1997; 87: 637.[Medline]
This article has been cited by other articles:
![]() |
K. Goldmann, J. Dieterich, and M. Roessler Laryngopharyngeal mucosal injury after prolonged use of the ProSealTM LMA in a porcine model: a pilot study: [Lesion de la muqueuse laryngo-pharyngee suite a une utilisation prolongee du masque larynge ProSealTM dans un modele porcin: une etude pilote] Can J Anesth, October 1, 2007; 54(10): 822 - 828. [Abstract] [Full Text] [PDF] |
||||
![]() |
D.-K. Kim, K.-Y. Rhee, W.-K. Kwon, T.-Y. Kim, and J.-E. Kang A heated humidifier does not reduce laryngo- pharyngeal complaints after brief laryngeal mask anesthesia: [L'utilisation d'un humidificateur chauffant ne reduit pas les douleurs laryngo-pharyngees lors d'une anesthesie breve avec un masque larynge] Can J Anesth, February 1, 2007; 54(2): 134 - 140. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. A. Gaitini, S. J. Vaida, M. Somri, V. Kaplan, B. Yanovski, R. Markovits, and C. A. Hagberg An Evaluation of the Laryngeal Tube(R) During General Anesthesia Using Mechanical Ventilation Anesth. Analg., June 1, 2003; 96(6): 1750 - 1755. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |