* From the Departments of Anesthesiology and
Neurosurgery, Faculty of Medicine, The University of Calgary, Calgary, Alberta, Canada.
Dr. David P. Archer, Department of Anesthesia, Foothills Medical Centre, 1403 29th Street NW, Calgary, Alberta T2N 2T9, Canada. Phone: 403-670-1667; Fax: 403-670-2425; E-mail: david.archer{at}CalgaryHealthRegion.ca
| Abstract |
|---|
|
|
|---|
Methods: Anesthetic factors were studied using a retrospective case-control design. The primary outcome measures were the duration of the surgical intervention; the recovery score and body temperature on arrival; and length of stay in the post-anesthetic care unit. Secondary outcome measures were estimated blood loss, perioperative transfusion requirements, and fluids administered.
Results: Seventy-six patients undergoing craniotomy in the MRI theatre were compared with a case-matched control group of patients who underwent neurosurgical interventions in the conventional operating room during the same time period. The only outcome measure that differed between the two groups of patients was the duration of surgery: the mean duration of procedures for patients who underwent imaging was 407 ± 143 min compared to 285 ± 122 min in the conventional operating theatre (P < 0.000). Actual time spent imaging accounted for approximately 100 min (83%) of the increased duration.
Conclusion: Our results do not support concerns that the iMRI suite is a "hostile" environment for the delivery of anesthesia for craniotomy. With the exception of an increased duration of the procedure, patients undergoing anesthesia with iMRI showed no differences from those operated in the conventional operating theatres.
| Introduction |
|---|
|
|
|---|
The delivery of anesthesia for patients undergoing MRI has been described as "making new demands on the anesthesiologist", both with respect to the "hostile environment"6 and related to the problems with medical devices in the MRI environment.7 For surgery using iMRI to be operational, it is important to establish that the increased demands upon the anesthetic team do not translate into increased risk for the patient. The delivery of anesthetic services in the iMRI environment has been well established and described, but the additional burden of complex neurosurgical procedures in the latter environment has not been evaluated. Specifically, we wanted to evaluate the possibility that there would be a substantial increase in the duration of cases related to the time required for imaging, the unfamiliar environment of the iMRI OR and modifications in the surgical approach based upon intraoperative imaging. In addition to prolonging the procedure, additional surgery prompted by intraoperative imaging might lead to increased blood loss and increased fluid requirements. Since the recovery from both volatile and opioid anesthetics can be prolonged by increases in exposure to the drugs8,9 we speculated that increased duration of anesthesia time could lead to prolonged emergence times. In combination with the lack of continuous temperature monitoring, increased procedure duration might lead to mild hypothermia on emergence. Although we are unaware of any specific data relating these factors to postoperative wound infection in patients undergoing craniotomy, we were concerned that the latter might be the case, and hence determined the infection rate in both groups of patients.
In December 1997, the mobile 1.5 T iMRI system became operational. The multidisciplinary research team, composed of neurosurgeons, physicists, magnetic resonance (MR) technologists, nurses and anesthesiologists, developed a plan for the staged implementation of iMRI, including safety evaluations and continuous quality improvement.
As part of the evaluation, we conducted a retrospective case-control study to compare the anesthetic aspects of craniotomy performed in the iMRI theatre with similar procedures performed in the conventional operating suites at our institution. Here we report on the anesthetic aspects of management in the iMRI theatre during the first two years of operation. Neurosurgical, nursing and technological aspects of this device have been reported previously.14
| Materials and methods |
|---|
|
|
|---|
Primary end points
The primary end points were: duration of the procedure, the recovery score and body temperature on arrival in the postanesthetic care unit (PACU), and the length of stay in the PACU. The duration of the procedure was measured from the time that the first vital signs were recorded in the anesthetic record to the time of leaving the operating theatre. Recovery from anesthesia was evaluated by the PACU nursing staff based upon: airway maintenance, respiratory rate, skin colour, and level of consciousness, with two points being the optimal score for each criterion, thus generating a maximum score of 8. Length of stay in PACU was measured from arrival until discharge or readiness to discharge as recorded in the PACU record. Treatment failure was defined as the requirement to limit the anesthetic or operative procedure because of technical problems involving the theatre.
Secondary end points
Secondary end points included estimated blood loss, intraoperative transfusion requirements and fluid administration, as determined from the anesthetic record. Characteristics of anesthetic management that were recorded included the position of surgery, drugs used for maintenance of anesthesia (opioids, volatile anesthetics, and nitrous oxide) and muscle relaxants.
Data analysis
Data sheets for the perioperative period were completed for each patient following review of the chart in the medical records department. Data were entered into a computerized spreadsheet for analysis (Excel® Microsoft Corp, USA). Quantitative data were analyzed by two-tailed t tests comparing the iMRI group with the conventional OR patients. Frequencies (e.g., use of isoflurane, opioids, muscle relaxants) were compared with contingency tables and subjected to the Chi square test. Statistical significance was inferred when P < 0.05.
Operative technique and iMRI procedure
The neurosurgical techniques and the mobile iMRI technology have been described in detail previously.13 Briefly, the iMRI technology at the University of Calgary uses a high field (1.5 T), mobile magnet to generate quality intraoperative images. Images are obtained intermittently during planned interruptions in surgery by moving the magnet over the patient (Figure
). This enables the use of conventional surgical instruments, which are removed from the field during imaging. Equipment that remains in the field, including the head clamp, operating table, and the anesthetic and monitoring devices that are attached to the patient are MR compatible (are not influenced by the magnetic field and do not alter the MR image). In its initial design, the superconducting magnet had an internal free base diameter of 62 cm, limiting the patient size to 100110 kg and limiting imaging in the lateral and prone positions because of the width of the shoulders. The latest superconducting magnet, with an internal free base diameter of 72 cm, permits imaging of patients up to 150 kg in all positions except sitting.
|
Anesthetic equipment
Selection criteria for each device used in the MR theatre were that 1) it not generate RF signals that would interfere with imaging (e.g., standard pulse oximeter); 2) there were no wires in which current induction during imaging would result in thermal injuries and RF interference.
The MRI compatible anesthetic machine used in the study was the Ohmeda Excel 210 MRI compatible (Datex Ohmeda, Helsinki, Finland). The patient monitor that was used was the Maglife® MRI monitoring system (GroupeBruker, Wissembourg, CEDEX, France), designed for use with MRI magnets up to 2 T. The monitoring system uses optical arterial oxygen saturation (SpO2) sensors, carbon fibre ECG electrodes, and incorporates high performance RF filters.
Variables measured in all patients included NIBP, SpO2, ECG and heart rate, end-tidal carbon dioxide (ETCO2) and respiratory rate, inspired and expired oxygen concentrations and end-tidal concentrations of nitrous oxide and volatile anesthetics. Intermittent axillary temperature monitoring was available and two invasive pressure monitors were available for use when indicated.
| Results |
|---|
|
|
|---|
Quality of matching
The demographic characteristics of the treatment groups is shown in Table I
. The degree of lesion matching is shown in Table III
. The majority (71/76) of patients matched on at least 3/5 of the match criteria.
|
|
Primary end points
The main finding of the present study was that procedures performed in the MR theatre took approximately two hours (122 min) longer to complete than those done in the conventional OR (Table I
). The majority of patients (57/76) in the MR theatre had two MR imaging sequences: an initial planning sequence before the surgical incision and an interdissection (prior to wound closure) or quality assurance MR study. Four patients had only an initial scan, 14 patients had surgical planning, interdissection and quality assurance studies, and one patient had four intraoperative studies. From the medical record, the sequence duration could only be determined for the planning and quality assurance (initial and final) scans. The average total time that was devoted to imaging was 101 ± 29 min. Recorded times for imaging therefore accounted for 83% of the difference in the length of the procedures between the conventional OR and the MR theatre.
Secondary end points
The increased OR time did not result in delayed emergence from anesthesia as measured by the initial PACU score or the length of stay in PACU (Table I
). Estimated blood loss, perioperative transfusion rate, postoperative hemoglobin concentration and intraoperative fluid administration were all similar in the two groups (Table I
). Despite the lack of intraoperative temperature monitoring and active measures to control temperature in patients managed in the MR theatre, initial tympanic membrane temperature on arrival was not different from that of patients managed in the conventional OR where these management modalities were available. (In the conventional OR group, 56/76 patients had temperatures monitored; we could not determine accurately how many patients had active heating/cooling measures applied intraoperatively).
Anesthetic management
Anesthetic management differed between the two groups in the use of nitrous oxide and in the choices of volatile anesthetics, opioids, and muscle relaxants (Table II
). The differences reflect the unavailability of an MR compatible desflurance vaporizer in the iMR OR (isoflurane was the sole volatile anesthetic available for iMRI patients) and personal preferences between the anesthesiologists responsible for the patients. Whereas the majority (> 95%) of anesthetics for cases in the MR theatre were administered by three anesthesiologists, 25 anesthesiologists were involved in the anesthetics delivered in the conventional OR. The differences in anesthetic management (Table II
) did not appear to influence the outcomes that we measured. Mannitol, 1 gkg-1, and dexamethazone 10 mg, were administered intravenously as a routine for tumour patients immediately following induction of anesthesia. It was also routine before induction of anesthesia to administer an iv dose of a cephalosporin or other appropriate antibiotic.
|
| Discussion |
|---|
|
|
|---|
Previous reports13,1113 of brain surgery using intraoperative MRI systems have focussed mainly on the imaging characteristics of the systems we are not aware of any controlled studies of craniotomy using iMRI. The anesthetic considerations for management of patients in MRI operating theatres have recently been reviewed.5 Due to the design of the mobile iMRI theatre, many of the potential hazards of anesthetic administration ascribed to MR OR5 have been avoided. The iMRI theatre is located close (three minutes' walk to the PACU) to the main surgical suite and adjacent to central emergency services and the intensive care unit. The theatre itself is standard size (7.58 x 10.4 m), allowing ample space for anesthetic equipment and easy physical approach to the patient. Patient access during imaging is of course limited by the presence of the magnet, but during surgery the access is the same as in a conventional OR. Using our system, there are no fringe fields during surgery, and even during imaging, fringe fields are reduced by active shielding, reducing the hazards of ferromagnetic objects and making the environment friendlier for monitoring devices.
Limitations of the present study include the retrospective design, which reduced the specificity of the data that we could collect, and the potential differences in surgical and anesthetic management that may have occurred because the latter were not standardized. The lesion characteristics (tumour + edema volume, size, extent of midline shift, and mass effect) could not be matched exactly because preoperative MR images were not available for all patients and these characteristics were frequently not reported. A randomized prospective design would have addressed some of these concerns, but would have had a major drawback: the variety of neurosurgical cases selected would have been severely limited and would not have permitted completion of the study within two years (a reasonable requirement for a safety study). The anesthetic management of the patients was not standardized, and the choice of anesthetic drugs differed between the iMRI and conventional OR patients (Table II
). Since a randomized clinical trial has previously shown that anesthetic choice for management of craniotomy does not alter anesthetic outcome,10 we are not surprised that no differences were detected in the present study. The impact of the potential differences in surgical management would seem to have been small, since imaging time accounted for 83% of the difference in duration of procedure for the two treatment groups. The present study was not designed to evaluate whether neurosurgical treatment guided by iMRI offers any advantage over conventional treatment or improves patient outcome to answer these questions will require a randomized clinical trial.
In summary, the present study was designed to evaluate the influence of iMRI perioperative anesthetic management for patients undergoing craniotomy. The results show that the use of an iMRI system in a dedicated OR prolonged the duration of the procedures but had minimal influence on other anesthetic measures of perioperative anesthetic outcome.
| Acknowledgments |
|---|
| Footnotes |
|---|
Revision received January 16, 2002. Accepted for publication November 13, 2001.
| References |
|---|
|
|
|---|
2 Sutherland GR, Kaibara T, Louw D, Hoult DI, Tomanek B, Saunders J. A mobile high-field magnetic resonance system for neurosurgery. J Neurosurg 1999; 91: 80413.[Medline]
3 Kaibara T, Saunders JK, Sutherland GR. Utility of a moveable 1.5 Tesla intraoperative MR imaging system. Can J Neurol Sci 1999; 26: 3136.[Medline]
4 Leblanc P, Aubry B, Gervin M. Moveable intraoperative magnetic resonance imaging systems in the OR. AORN J 1999; 70: 25467.[Medline]
5 Manninen PH, Kucharczyk W. A new frontier: magnetic resonance imaging-operating room. J Neurosurg Anesth 2000; 12: 1418.[Medline]
6 Turner JM. Anesthesia for Neuroradiology. In: Matta BF, Menon DK, Turner JM (Eds.). Textbook of Neuroanesthesia and Critical Care. London: Greenwich Medical Media Ltd., 2000: 401.
7 Burnstein RM, Menon DK. Anaesthesia for magnetic resonance imaging. In: Matta BF, Menon DK, Turner JM (Eds.). Textbook of Neuroanaesthesia and Critical Care. London: Greenwich Medical Media Ltd., 2000: 411.
8 Bailey JM. Context-sensitive half-times and other decrement times of inhaled anesthetics. Anesth Analg 1997; 85: 6816.[Abstract]
9 Bailey PL, Egan TD, Stanley TH. Intravenous opioid anesthetics. In: Miller RD (Ed.). Anesthesia, fifth edition. New York: Churchill Livingstone, 2000; 31720.
10 Todd MM, Warner DS, Sokoll MD, et al. A prospective, comparative trial of three anesthetics for elective supratentorial craniotomy. Propofol/fentanyl, isoflurane/nitrous oxide, and fentanyl/nitrous oxide. Anesthesiology 1993; 78: 100520.[Medline]
11 Bernstein M, Al-Anazi AR, Kucharczyk W, Manninen P, Bronskill M, Henkelman M. Brain tumor surgery with the Toronto open magnetic resonance imaging system: preliminary results for 36 patients and analysis of advantages, disadvantages, and future prospects. Neurosurgery 2000; 46: 9009.[Medline]
12 Black P, Moriarty T, Alexander III E, et al. Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. Neurosurgery 1997; 41: 83145.[Medline]
13 Black P, Alexander III E, Martin C, et al. Craniotomy for tumor treatment in an intraoperative magnetic resonance imaging unit. Neurosurgery 1999; 45: 42333.[Medline]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||