| Abstract |
|---|
|
|
|---|
Methods: Twenty patients who underwent elective spinal surgery were studied. Patients were anesthetized with 50% nitrous oxide in oxygen, fentanyl, and propofol to maintain the bispectral index (BIS) score around 50. MEP in response to a multipulse transcranial electrical stimulation at stimulus sites of C3C4 were recorded over the right abductor pollicis brevis muscle. Changes of peak-to-peak amplitude and onset latency of MEP, BIS score before and after surgical stimuli were evaluated. Propofol plasma concentration was measured at the same time points.
Results: Both MEP amplitude and latency did not change significantly after surgical stimuli although BIS increased significantly (48 ± 6 to 58 ± 5; P < 0.05). Plasma propofol concentration was maintained at the same level between the two measurement points (3.3 ± 0.7 to 3.3 ± 0.7 µgmL-1). There was no relation between BIS change and changes of MEP amplitude and latency, and propofol plasma concentration.
Conclusion: MEP to the transcranial electrical stimulation under a constant and clinically appropriate blood propofol concentration are not affected by surgical noxious stimuli.
| Introduction |
|---|
|
|
|---|
Multiple investigators have documented the usefulness of computer processed electroencephalography (EEG), such as the bispectral index (BIS), to quantify assessment of anesthetic depth.1113 In general, anesthetic depth is affected by noxious stimuli. BIS appears to be sensitive to the changes in anesthetic depth produced by noxious stimuli, including surgery.1113 Furthermore, it is conceivable that noxious stimuli might also increase evoked potential signals, including MEP. If the arousing effect of surgical noxious stimuli affects MEP even under constant anesthetic concentration, the modification of monitoring results might lead to a misestimation of motor function. Simultaneously, adjustment of the anesthetic regimen would be required to provide adequate anesthesia against noxious stimuli. The present study was conducted to investigate whether MEP to transcranial electrical stimulation under constant blood propofol concentration are affected by the arousing effect of surgical noxious stimuli using BIS as an assessment of anesthetic depth.
| Materials and methods |
|---|
|
|
|---|
All patients were premedicated with roxatidine (H2 blocker) 75 mg orally two hours preoperatively. Anesthesia was induced with propofol 1.52.5 mgkg-1, fentanyl 78 µgkg-1 and vecuronium 0.1 mgkg-1 and maintained with 50% nitrous oxide in oxygen, propofol 36 mgkg-1hr-1 and fentanyl 45 µgkg-1hr-1. After the trachea was intubated, the lungs were ventilated mechanically to maintain PaCO2 between 3540 mmHg. Systolic blood pressure was maintained at 100130 mmHg. When hypotension or hypertension was observed, a bolus of ephedrine or nicardipine was administered.
Muscle relaxation was monitored and controlled by the following. Compound muscle action potentials from the right abductor pollicis brevis muscle (APB) in response to supramaximal electrical stimulation (constant-current square wave pulses of 0.2 msec duration) of the median nerve at the wrist were recorded as a means of assessing the degree of neuromuscular blockade. This response is known in the neurophysiologic literature as the muscle (M) response.14 The control value was defined as that at admission to the operating room without the effect of vecuronium. The level of M-response was maintained at 4050% of control with a continuous infusion of vecuronium. Other monitoring included the electrocardiogram, intraarterial pressure, oxygen saturation by pulse oxymetry, end-tidal CO2 concentration, and rectal temperature.
Transcranial stimulation was performed using a multipulse device (D-185; Digitimer, Welwyn, Garden City, UK). A train-of-five pulses with an interstimulus interval of 2 msec were used as in our previous study.7 The outputs were delivered to the scalp by a single pair of 14.5 mm silver disc electrodes, applied to C3 (anode) and C4 (cathode); (international 1020 system). Five consecutive stimulations at C3 and C4 were made. The stimulus intensity was set at 700 V.
MEP were recorded from the right APB (the same site as for recording of M-response). Evoked myographic responses were amplified with a 0.33 kHz band pass filter and displayed on oscilloscopes (MEB-5508; Nihon Koden, Tokyo, Japan). Experimental MEP study was performed after the induction of anesthesia and before the start of surgery. Peak-to-peak amplitudes and onset latencies were monitored. The mean amplitude and latency were calculated from five consecutive responses to stimulation using a pair of C3C4 disc electrodes.
The EEG signal was recorded using the Aspect A-1000 EEG monitor (Aspect Medical System, Natick, MA, USA). Silver-silver chloride EEG pads (Zipprep; Aspect Medical Systems) were attached to patients forehead according to a standard montage.15 The low - and high - frequency filters were set to 0.25 Hz and 30 Hz, respectively. By ten minutes before the start of surgery, the propofol infusion rate was adjusted to maintain stable BIS score around 50. The propofol infusion rate was not changed thereafter.
To investigate whether MEP to transcranial electrical stimulation under constant blood propofol concentration are affected by arousing effect of surgical noxious stimuli, MEP were collected two minutes before and after the start of surgery. In most cases, approximately 60 min had passed after induction of anesthesia when the first MEP collections were conducted. The start of surgery in this study was defined when the initial surgical incision was made. No interventions were made to standardize the degree of stimulation by surgeons because surgical sites were different among patients. At same time points, BIS score, mean arterial pressure (MAP), and heart rate (HR) were recorded and blood samples were collected to confirm that propofol plasma concentration remained constant. Five millilitres of blood were drawn into a heparinized syringe, collected into a glass tube, centrifuged for ten minutes at 3000 rpm, and 2.0 mL of plasma were stored at -20°C for propofol analysis. Plasma concentrations of propofol were determined by high-performance liquid chromatography.
Statistical analysis
Because MEP amplitude-related data did not appear to be distributed normally, they are presented as median, and tenth, 25th, median, 75th, and 90th percentiles. MEP latency-related data are expressed as mean ± SD. A paired t test to compare physiologic variables, BIS score, propofol concentration, and latency of MEP between the two time points, Wilcoxon signed-ranks test was used to compare amplitudes of MEP. The relationships between BIS and MEP amplitude and latency, and propofol concentration before and after the start of surgery were evaluated by Pearsons correlation. Because these values varied with individual patients, especially MEP amplitude and BIS score, the relationships were also analyzed using percent change of these values. Any change of MEP amplitude of more than 50% was defined as a significant modification according to Zhou et al.16 because within- patient variability of MEP, which may lead to a misinterpretation of the MEP, is generally observed.17,18 Results were considered significant at P < 0.05.
| Results |
|---|
|
|
|---|
MEP were recorded successfully in all but one patient. MEP peak-to-peak amplitude did not change significantly after the start of surgery (Figure 1
) although BIS score did increase significantly (48 ± 6 to 58 ± 5; P < 0.05). MEP latency did not change (20.9 ± 1.8 to 20.9 ± 1.9 sec). Plasma propofol concentration was constant (3.3 ± 0.7 to 3.3 ± 0.7 µgmL-1). Absolute and percent changes in BIS were not related to changes in MEP latency or amplitude or propofol concentration (Figures 2 and 3![]()
). MAP and HR did not change significantly (78 ± 9 to 81 ± 11 mmHg and 63 ± 10 to 67 ± 14 beatsmin-1, respectively). No patient showed a significant positive change of MEP amplitude.
|
|
|
| Discussion |
|---|
|
|
|---|
Although a number of authors have reported the effects of anesthetics on MEP induced by motor cortex stimulation, the effect of noxious surgical stimuli on intraoperative MEP monitoring remains unclear. The most plausible explanation for our results is that the effect of an anesthetic on the spinal cord is independent of its supraspinal effects.1924 It is likely that synaptic transmission is the primary site at which anesthetics suppress MEP, specifically at the level of the spinal interneuronal or motoneuronal systems.4 These spinal systems and their evoked potentials do not appear to be affected by the change in anesthetic depth at the supraspinal level. Otherwise, MEP amplification by surgical stimuli might be masked by five-pulse transcranial electrical stimulation, which is an effective way of achieving discharge in a large set of spinal motoneurons. In other words, the amplification by surgical stimuli is only allowed to go so far; however, our study design did not allow the physiology of this response to be determined.
There are several limitations to the study protocol that must be discussed. The effects of different propofol concentrations or BIS scores on our results could be important. In light of ethical concerns, we wanted to avoid higher BIS scores using lower propofol doses. It has been reported that a BIS of 4055 is usually required during general anesthesia. We targeted a BIS of approximately 50 for this study, which required a plasma propofol concentration of over 3 µgmL-1.1113 This is recognized as a clinically appropriate concentration and probably higher than those used in other MEP studies.25 Using a clinically appropriate propofol-based anesthetic, may, possibly, have limited our ability to test our study hypothesis. However, the surgical stimuli appeared to be sufficient to change anesthetic depth even under clinically appropriate propofol-based anesthesia.
The question may also be raised as to whether the anesthetic depth truly changed after the noxious stimuli. The significance of an increase in mean BIS from 4858 is unclear. The absence of an increase in MAP or HR despite an increase in BIS raises questions about the clinical significance of the BIS increase. Yet, we believe the increase in BIS indicated a change in anesthetic depth, as BIS scores have been reported to be clinically reliable in this assessment.1113 Furthermore, BIS increases in response to noxious stimuli prior to or in the absence of hemodynamic or motor reactivity as evidence of inadequate anesthesia in some patients.26
Our results support the use of MEP monitoring; however, the response to alterations in anesthetic depth following noxious stimuli remains unclear, creating a dilemma between the need to provide adequate anesthesia and the desire to consistently obtain MEP recordings. It is true that the use of agents that depress MEP or modifications to their concentration in response to noxious stimuli should be avoided. As our results showed, it is also true that anesthetic depth is changed by noxious stimuli during MEP monitoring. Over this decade, methods of intraoperative MEP monitoring have developed greatly, but we should strive to improve the quality of anesthesia during intraoperative MEP monitoring.
In conclusion, we have demonstrated that MEP to transcranial electrical stimulation under a constant and clinically appropriate propofol blood concentration are not affected by surgical noxious stimuli.
| Acknowledgments |
|---|
| Footnotes |
|---|
Revision received October 17, 2002. Accepted for publication June 11, 2002.
| References |
|---|
|
|
|---|
2 Kalkman CJ, Drummond JC, Ribberink AA. Low concentrations of isoflurane abolish motor evoked responses to transcranial electrical stimulation during nitrous oxide/opioid anesthesia in humans. Anesth Analg 1991; 73: 4105.
3 Kawaguchi M, Inoue S, Kakimoto M, et al. The effect of sevoflurane on myogenic motor-evoked potentials induced by single and paired transcranial electrical stimulation of the motor cortex during nitrous oxide/ketamine/fentanyl anesthesia. J Neurosurg Anesthesiol 1998; 10: 1316.[Medline]
4 Zentner J, Albrecht T, Heuser D. Influence of halothane, enflurane, and isoflurane on motor evoked potentials. Neurosurgery 1992; 31: 298305.[Medline]
5 van Dongen EP, ter Beek HT, Aarts LP, et al. The effect of two low-dose propofol infusions on the relationship between six-pulse transcranial electrical stimulation and the evoked lower extremity muscle response. Acta Anaesthesiol Scand 2000; 44: 799803.[Medline]
6 van Dongen EP, ter Beek HT, Schepens MA, et al. The influence of nitrous oxide to supplement fentanyl/low-dose propofol anesthesia on transcranial myogenic motor-evoked potentials during thoracic aortic surgery. J Cardiothorac Vasc Anesth 1999; 13: 304.
7 Kawaguchi M, Sakamoto T, Inoue S, et al. Low dose propofol as a supplement to ketamine-based anesthesia during intraoperative monitoring of motor-evoked potentials. Spine 2000; 25: 9749.[Medline]
8 Ubags LH, Kalkman CJ, Been HD, Porsius M, Drummond JC. The use of ketamine or etomidate to supplement sufentanil/N2O anesthesia does not disrupt monitoring of myogenic transcranial motor evoked responses. J Neurosurg Anesthesiol 1997; 9: 22833.[Medline]
9 Thees C, Scheufler KM, Nadstawek J, et al. Influence of fentanyl, alfentanil, and sufentanil on motor evoked potentials. J Neurosurg Anesthesiol 1999; 11: 1128.[Medline]
10 Zentner J, Thees C, Pechstein U, Scheufler KM, Wurker J, Nadstawek J. Influence of nitrous oxide on motor-evoked potentials. Spine 1997; 22: 10026.[Medline]
11 Vernon JM, Lang E, Sebel PS, Manberg P. Prediction of movement using bispectral electroencephalographic analysis during propofol/alfentanil or isoflurane/alfentanil anesthesia. Anesth Analg 1995; 80: 7805.[Abstract]
12 Sebel PS, Lang E, Rampil IJ, et al. A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect. Anesth Analg 1997; 84: 8919.[Abstract]
13 Struys MM, De Smet T, Versichelen LF, Van de Velde S, Van den Broecke R, Mortier EP. Comparison of closed-loop controlled administration of propofol using bispectral index as the controlled variable versus "standard practice" controlled administration. Anesthesiology 2001; 95: 617.[Medline]
14 Kalkman CJ, Drummond JC, Kennelly NA, Patel PM, Partridge BL. Intraoperative monitoring of tibialis anterior muscle motor evoked responses to transcranial electrical stimulation during partial neuromuscular blockade. Anesth Analg 1992; 75: 5849.
15 Rampil IJ, Holzer JA, Quest DO, Rosenbaum SH, Correll JW. Prognostic value of computerized EEG analysis during carotid endarterectomy. Anesth Analg 1983; 62: 18692.
16 Zhou HH, Kelly PJ. Transcranial electrical motor evoked potential monitoring for brain tumor resection. Neurosurgery 2001; 48: 107581.[Medline]
17 van Dongen EP, ter Beek HT, Schepens MA, et al. Within patient variability of lower extremity muscle responses to transcranial electrical stimulation with pulse trains in aortic surgery. Clin Neurophysiol 1999; 110: 11448.[Medline]
18 Woodforth IJ, Hicks RG, Crawford MR, Stephen JP, Burke DJ. Variability of motor-evoked potentials recorded during nitrous oxide anesthesia from the tibialis anterior muscle after transcranial electrical stimulation. Anesth Analg 1996; 82: 7449.[Abstract]
19 Antognini JF, Schwartz K. Exaggerated anesthetic requirements in the preferentially anesthetized brain. Anesthesiology 1993; 79: 12449.[Medline]
20 Rampil IJ, Mason P, Singh H. Anesthetic potency (MAC) is independent of forebrain structures in the rat. Anesthesiology 1993; 78: 70712.[Medline]
21 Antognini JF, Carstens E, Tabo E, Buzin V. Effect of differential delivery of isoflurane to head and torso on lumbar dorsal horn activity. Anesthesiology 1998; 88: 105561.[Medline]
22 Antognini JF, Wang XW, Piercy M, Carstens E. Propofol directly depresses lumbar dorsal horn neuronal responses to noxious stimulation in goats. Can J Anesth 2000; 47: 2739.
23 Zhou HH, Jin TT, Qin B, Turndorf H. Suppression of spinal cord motoneuron excitability correlates with surgical immobility during isoflurane anesthesia. Anesthesiology 1998; 88: 95561.[Medline]
24 Antognini JF, Carstens E, Buzin V. Isoflurane depresses motoneuron excitability by a direct spinal action: an F-wave study. Anesth Analg 1999; 88: 6815.
25 Casati A, Fanelli G, Casaletti E, et al. Clinical assessment of target-controlled infusion of propofol during monitored anesthesia care. Can J Anesth 1999; 46: 2359.
26 Luginbuhl M, Schnider TW. Detection of awareness with the bispectral index: two case reports. Anesthesiology 2002; 96: 2413.[Medline]
This article has been cited by other articles:
![]() |
N. Nathan, F. Tabaraud, F. Lacroix, D. Moulies, X. Viviand, A. Lansade, G. Terrier, and P. Feiss Influence of propofol concentrations on multipulse transcranial motor evoked potentials Br. J. Anaesth., October 1, 2003; 91(4): 493 - 497. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |