| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |

* From the Department of Anaesthesia, Royal National Orthopaedic Hospital, Stanmore, United Kingdom; and
the Department of Anesthesiology, Duke University Medical Center, Durham, North Carolina, USA.
Address correspondence to: Dr. Andrew McLeod, Department of Anaesthetics, Queen Alexandra Hospital, Cosham, Portsmouth, PO6 3LY, United Kingdom. Phone: +44 2392 286279; Fax: +44 2392 286681; E-mail: andrew.mcleod{at}porthosp.nhs.uk
| Abstract |
|---|
|
|
|---|
Clinical features: Eleven patients scheduled for corrective scoliosis surgery were studied. The spine was examined ultrasonically using a portable ultrasound system with a 38-mm linear probe in two-dimensional B mode. The angulation of the probe head (measured using an inclinometer held in alignment with its long axis) at which the echo signals from the laminae became level on the screen was taken to correspond to the degree of vertebral rotation. The least rotated (most neutral) vertebral interspace was located, and a supervised anesthesiology trainee then performed epidural catheter insertion, using a loss-of-resistance technique. Bupivacaine 0.125% with fentanyl 4 µg·mL1 was infused after surgery, and successful epidural placement was indicated by the presence of effective analgesia and loss of sensation to cold stimuli. In ten patients, the neutral space could be identified, while in one, the least rotated space was measured at 15° from the horizontal. Epidural catheterization was successful in eight of 11 patients at the identified level. In two other patients, the space above was employed. The information was described as helpful in seven patients.
Conclusion: We conclude that ultrasonography may have a potential role to facilitate insertion of epidural catheters in patients with scoliosis.
| Introduction |
|---|
|
|
|---|
| Methods |
|---|
|
|
|---|
Assessment of the spine, and insertion of the epidural catheter was performed after induction of anesthesia, which followed our institutions routine practice in pediatric and young-adult patients with scoliosis. Each patient was placed in the lateral position, and the same investigator examined the spine ultrasonically. A portable ultrasound system (Sonosite 180®, Sonosite Ltd, Hitchin, UK) with a 38-mm linear probe was used, which could insonate to a depth of 70 mm. The spine was examined in two-dimensional B mode at each level to assess the degree of rotation, using the method described by Suzuki and colleagues.4 The probe head was placed in the space between two spinous processes, perpendicular to the long axis of the spine. Rotation (relative to the horizontal plane) was measured in degrees using an inclinometer held in careful alignment with the long axis of the probe, as shown in Figure 1
. The laminae appear as bright echogenic bands at 2 to 4 cm depth either side of the midline, as shown in Figure 2
. When they appear level in the ultrasound image, the angulation of the probe head corresponds to the degree of rotation of the vertebral bodies. The level of the most neutral space was estimated by counting the spinous processes, and recorded. An experienced anesthesia trainee then attempted to insert an epidural catheter at this level, following instructions to direct the needle in the horizontal plane. A midline approach was employed, using a 16-gauge Tuohy needle (SIMS Portex, Hythe, Kent, UK) and loss-of-resistance technique. An epidural catheter was inserted, but local anesthetic was not instilled until perioperative spinal cord monitoring had been discontinued. An initial bolus dose of 5 to 10 mL 0.25% bupivacaine, followed by an infusion of 0.125% bupivacaine with fentanyl 4 µg·mL1 was administered. Confirmation of correct placement was based upon effective analgesia, and the presence of bilateral loss of sensation to cold, assessed in the postoperative care unit. Pain was scored on a simple numerical analogue scale 0 to 4 where 0 represents no pain, and 4, extreme pain. The anesthesiologist performing epidural insertion was asked whether the ultrasound information had been helpful, i.e., they had been able to successfully insert an epidural catheter with the needle in a horizontal orientation. Descriptive statistics were calculated using Microsoft Excel® software.
|
|
| Results |
|---|
|
|
|---|
|
| Discussion |
|---|
|
|
|---|
In our study, we did not attempt to corroborate the ultrasound assessments with radiological measurements, or perform computed tomography scans of the patients. The recorded measurements did not take into account vertebral deformation, where vertebrae are distorted, as well as rotated. Also, we measured rotation relative to the horizontal plane, although this approach may not have corresponded exactly to the patients own midline saggital plane, despite careful positioning. However, anesthesiologists are familiar with directing a needle in the horizontal plane, and it is our view that this space could be the most useful one to identify. The participating trainees all had more than four years experience in anesthesiology, and were proficient in the technique of inserting epidural catheters into patients with normal spines. We therefore believed that they could potentially obtain most benefit from information derived from this technique.
A number of factors influence the difficulty of inserting epidural catheters, such as estimating the depth of the epidural space, and the longitudinal angulation of the spinous processes. In the scoliotic spine, the rotation of the vertebral bodies adds a further unknown variable. The spinous processes face into the concavity of the curve, which may also be counter-intuitive to those unfamiliar with scoliosis. At our institution, all trainees are instructed in the anatomical distortions of the scoliotic spine. The Cobb angle is routinely measured from preoperative radiographs, but its relationship with vertebral rotation is complex. Moe and Nash have described a technique that estimates rotation from radiographs,6 but this method requires some familiarity with spinal radiographs, and the information derived may not easily translate to the clinical situation. In this study, the participating anesthesiology trainees were not explicitly made aware of radiological information, but relied on the information we had obtained from ultrasound.
The technique described by Suzuki et al.,4 was intended for the assessment of scoliosis only, rather than for guiding interventions, and its potential application in anesthesia has not been described previously. Ultrasound has been successfully used to estimate the depth of the epidural space in obstetric patients,1 and to improve the accuracy with which anesthesiologists identify the lumbar interspace level.2,3 In obstetrical practice, Grau et al. reported that ultrasound assistance reduced the number of epidural insertion attempts.7 The same group reported improved learning curves for trainees performing their first 60 epidural cannulations using ultrasound guidance compared to those not using the technique.8 Ultrasound has wider applications, including central venous cannulation and peripheral nerve blockade, which are gaining in acceptance.9 Indeed, ultrasonography is now being seen as an essential tool in any practice performing central venous access, as the British National Institute for Clinical Excellence (NICE) recommended in the 2002 NICE clinical guidelines for the use of ultrasound in central venous cannulation.10 Many authors have also recently described the success of ultrasound-guided brachial plexus blockade aiding visualization of needle placement and local anesthetic spread in a real-time manner.11,12 In the future, use of ultrasound for invasive procedures may increasingly be seen as best practice, particularly in training contexts.9,13
Although a number of papers describe the success of ultrasound in facilitating lumbar and caudal epidural cannulation,7,8,14 this is the first case series describing its use in epidural cannulation of the more difficult thoracic region, in patients with significant axial rotation of their vertebrae due to severe scoliosis requiring surgical correction. A large randomized controlled trial is warranted to assess if this novel technique increases the success rate of epidural catheter placement, as well as improving postoperative analgesia.
| Acknowledgments |
|---|
| Footnotes |
|---|
Accepted for publication January 17, 2005. Revision accepted March 29, 2005.
| References |
|---|
|
|
|---|
2 Furness G, Reilly MP, Kuchi S. An evaluation of ultrasound imaging for identification of lumbar intervertebral level. Anaesthesia 2002; 57: 27780.[Medline]
3 Watson MJ, Evans S, Thorp JM. Could ultrasonography be used by an anaesthetist to identify a specified lumbar interspace before spinal anaesthesia? Br J Anaesth 2001; 90: 50911.
4 Suzuki S, Yamamuro T, Shikata J, Shimizu K, Iida H. Ultrasound measurement of vertebral rotation in idiopathic scoliosis. J Bone Joint Surg 1989; 71-B: 2525.
5 Cobb JR. Outline for the study of scoliosis. In: Blount WP, Banks SW (Eds). The American Academy of Orthopaedic Surgeons, Instructional Course Lectures, vol 5. Ann Arbor, MI: JW Edwards; 1948: 26175.
6 Nash CL Jr, Moe JH. A study of vertebral rotation. J Bone Joint Surg (Am) 1969; 51-A: 2239.
7 Grau T, Leipold RW, Conradi R, Martin E, Motsch J. Ultrasound imaging facilitates localization of the epidural space during combined spinal and epidural anesthesia. Reg Anesth Pain Med 2001; 26: 647.[Medline]
8 Grau T, Bartusseck E, Conradi R, Martin E, Motsch J. Ultrasound imaging improves learning curves in obstetric epidural anesthesia: a preliminary study. Can J Anesth 2003; 50: 104750.
9 Hatfield A, Bodenham A. Ultrasound: an emerging role in anaesthesia and intensive care. Br J Anaesth 1999; 83: 789800.
10 National Institute for Clinical Excellence. Final Appraisal Determination. Ultrasound locating devices for placing central venous catheters. Available from URL; http://www.nice.org.uk/page.aspx?o=35419.
11 Sandhu NS, Capan LM. Ultrasound-guided infraclavicular brachial plexus block. Br J Anaesth 2002; 89: 2549.
12 Chan VW, Perlas A, Rawson R, Odukoya O. Ultrasound-guided supraclavicular brachial plexus block. Anesth Analg 2003; 97: 15147.
13 Scott DH. In the country of the blind, the one-eyed man is king, Erasmus (1466-1536) (Editorial). Br J Anaesth 1999; 82: 8201.
14 Chen CP, Tang SF, Hsu TC, et al. Ultrasound guidance in caudal epidural needle placement. Anesthesiology 2004; 101: 1814.[Medline]
This article has been cited by other articles:
![]() |
B. Tsui, D. Dillane, J. Pillay, and A. Walji Ultrasound imaging in cadavers: training in imaging for regional blockade at the trunk: [L'imagerie par ultrason pratiquee sur des cadavres : formation en imagerie pour les blocs regionaux au niveau du tronc] Can J Anesth, February 1, 2008; 55(2): 105 - 111. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. W.H. Peng and A. Rofaeel Using ultrasound in a case of difficult epidural needle placement. Can J Anesth, March 1, 2006; 53(3): 325 - 326. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |