CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Résumé de cet Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, D. M.
Right arrow Articles by Camporota, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, D. M.
Right arrow Articles by Camporota, L.
Canadian Journal of Anesthesia 53:188-193 (2006)
© Canadian Anesthesiologists' Society, 2006

Cardiothoracic Anesthesia, Respiration and Airway

Advantages of ProSealTM and SLIPATM airways over tracheal tubes for gynecological laparoscopies

[Les avantages des canules ProSealTM et SLIPATM sur les tubes endotrachéaux pour les laparoscopies gynécologiques]

Donald M. Miller, FFA SA PhD and Luigi Camporota, MD MRCP

From the Department of Anaesthetics, Guy’s, King’s and St. Thomas’ School of Medicine, King’s College London, London, United Kingdom.

Address correspondence to: Dr. Donald M. Miller, GKT Department of Anaesthetics, 2nd Floor, NGH, Guy’s Hospital, London SE1 9RT, United Kingdom. Phone: +44 20 71880637; Fax: +44 20 71880642; E-mail: donald.miller{at}kcl.ac.uk


    Abstract
 TOP
 Abstract
 Introduction
 Materials and methods
 Airway insertion times
 Results
 Discussion
 References
 
Purpose: To compare the efficacy of the ProSeal LMATM and SLIPATM supralaryngeal airways (SLA) with the standard tracheal tube (TT) in 150 consecutive day-case laparoscopic gynecological surgery procedures requiring general anesthesia.

Methods: One hundred and fifty patients were randomized into three groups. An identical general anesthesia technique was used in all patients apart from the addition of muscle relaxants and reversal drugs in the TT group. Patients were excluded if there were risk factors for gastroesophageal reflux. Ease of use, quality of seal, ventilation, systolic pressure, response to intubation, side effects and operating room time were assessed.

Results: Both ProSeal LMATM and SLIPATM were easy to insert (100% success) and ventilate with respective mean (standard deviation) maximum sealing pressures of 31 (4.6) and 30 (5.2) cmH2O (P = 0.4) with no muscle relaxants. The seal quality in both ProSeal LMATM and SLIPATM permitted the use of low flows, 485 (291) and 539 (344) mL·min–1 (P = 0.2) respectively, although in the TT group significantly lower flows [377 (124) mL·min–1], (P < 0.01) were achieved. Systolic pressure in the SLA groups was more stable in response to insertion than in the TT. With ProSealTM there was a lower incidence of sore throats than with TT (30% vs 57%), (P < 0.05), but there was a lesser difference as compared with SLIPATM (30% vs 49%), (P > 0.05). With both SLAs, there was a significant reduction in operating room time (> three minutes), (P < 0.001).

Conclusions: These results suggest that the ProSeal LMATM (reusable) and SLIPATM (single-use) SLAs were easy to use without requiring muscle relaxants, and reduce operating room time compared to the TT technique in day case laparoscopies.


    Introduction
 TOP
 Abstract
 Introduction
 Materials and methods
 Airway insertion times
 Results
 Discussion
 References
 
THE recent advent of newer designs in supra-laryngeal airways (SLAs) provides a possible alternative technique to the traditional use of tracheal tubes during laparoscopies. The advantages of SLAs are related to the fact that they may be inserted easily using a blind technique, and they allow for effective positive pressure ventilation.

The Streamlined LIner of the Pharynx Airway (SLIPATM; SLIPAmed SA Pty Ltd, Cape Town, South Africa) is a new type of SLA, fabricated from soft plastic with an anatomically preformed shape that lines the pharynx. This means positive pressure ventilation may be achieved without a cuff inflating mechanism that is required in other airway types such as the laryngeal mask (LM). A full description of this device and its limitations is accessible on the SLIPA website (www.slipa.com). Briefly, it comprises a hollow, blow-moulded chamber shaped like a boot with toe (T), bridge (B) that seals at the base of the tongue and a heel (H), which anchors the device in a stable position between the esophagus and nasopharynx. It is not necessary for the SLIPATM to be tied or strapped into position (Figure 1Go). The chamber provides a large capacity (50 mL compared to 3.5 mL in the LM) for providing maximum but limited storage of regurgitated liquids should they arise from the stomach, thus preventing their inadvertent overflow into the trachea.1 The safety advantages of simplicity and minimization of aspiration risk of a device without a cuff inflating mechanism necessitates double the number of sizes in order to obtain a good quality seal for positive pressure ventilation. The aspiration protection characteristics of both the SLIPATM and ProSealTM LM have been compared favourably with those of the LM in a laboratory study.1


Figure 1
View larger version (90K):
[in this window]
[in a new window]
 
FIGURE 1 SLIPATM shown in position with the toe (T) at the entrance to the esophagus, the bridge (B) where sealing takes place at the base of the tongue and the heel (H) in the nasopharynx.

 
In contrast with the use of tracheal tubes (TTs), the use of muscle relaxants may not be required when inserting or using SLAs for laparoscopies. The use of a muscle relaxant appears to prolong the duration of the whole procedure.2 Conflicting evidence regarding time saving relates to different techniques used and the actual times that were measured.3 We hypothesized that SLAs should provide satisfactory conditions for positive pressure ventilation without the use of muscle relaxants, with a reduction in side-effects and operating room time, when compared with a standard TT technique tube for day-case laparoscopic surgery. To test our hypothesis, two SLAs designed to minimize aspiration risk in the presence of regurgitation were chosen. These were the reusable ProSeal LMATM (PLMA; The Laryngeal Mask Company Ltd, Maidenhead, UK) and the single-use SLIPATM.


    Materials and methods
 TOP
 Abstract
 Introduction
 Materials and methods
 Airway insertion times
 Results
 Discussion
 References
 
Subjects
Over a six-month period, 158 fasted healthy adult females (American Society of Anesthesiologists I–II) scheduled to undergo laparoscopic gynecological procedures under general anesthesia were asked to participate in the study, for which local Research Ethics Committee approval and written informed consent were obtained. Three patients refused to be part of the trial. The sample size was determined from the results of similar studies.13 Patients (five) were excluded if they suffered from diabetes mellitus, morbid obesity or gastroesophageal reflux, were pregnant, or at high risk from pulmonary aspiration. Patients were randomized into one of three groups using Excel random number generation. The anesthesiologist was unaware of which airway (PLMA, the SLIPATM or the standard TT) was to be used until five to ten minutes before administering anesthesia. The size of the PLMA was chosen, based upon body weight, according to the manufacturer’s recommendations (size 3 if < 50 kg or size 4 if > 50 kg). The SLIPATM size was chosen by matching the width across the thyroid cartilage with that of the bridge of the SLIPATM (Figures 2A, 2BGo). There are three sizes primarily for women, 47, 49 and 51 mm across the bridge of the SLIPATM. The equivalent respective PLMA: SLIPATM sizes used in these women were 3: 47 and 4: 49 or 51.


Figure 2
Figure 2
View larger version (270K):
[in this window]
[in a new window]
 
FIGURE 2 A) Sizing dimension between left and right cornu of thyroid cartilage by palpation and B) matching the dimension at level of SLIPATM bridge.

 
For the PLMA and SLIPATM groups, general anesthesia was induced with midazolam 1 mg iv and fentanyl 1 µg·kg–1 iv, followed within two minutes by propofol 2 to 3 mg·kg–1 iv. One minute later a single operator (D.M.) inserted the airway device as out-lined in the manufacturer’s instructions. If the initial attempt at insertion of either airway was unsuccessful, the patient received a supplementary dose of propofol up to 1 mg·kg–1 iv and the head was repositioned to permit one further attempt. If the second attempt was unsuccessful, it was to be recorded as a failure. For the TT group, the same induction drugs and doses were used but with the addition of atracurium 25 mg iv two minutes prior to intubation. Anesthesia was maintained with sevoflurane (3.5–4%) in oxygen and air, with supplementary fentanyl (50–100 µg iv) or morphine (5–10 mg iv) given as required with iv fluids.

For all patients in whom successful airway placement was achieved, the lungs were ventilated mechanically through a circle system using a single Frontline 560 anesthetic machine (Blease Medical Equipment Ltd, Buckinghamshire, UK). The ventilator on this machine is time-cycled and volume-controlled with a rising bellows. The inspiration: expiration ratio was varied between 1:1 to 1:2 with a respiratory rate of 18 min–1 in order to use the lowest inflation pressure to achieve adequate ventilation. The tidal volume was adjusted to achieve an end tidal CO2 value of 30 to 40 mmHg. Mild hyperventilation combined with the use of opioids meant that patients were not breathing spontaneously throughout the abdominal insufflation phase of the procedure. Systolic pressure was measured non-invasively before anesthesia, immediately following induction but before airway placement, and within two minutes of placing the airway. After surgery, women in the TT group received neostigmine and glycopyrrolate to reverse neuromuscular block. The time from start of deflation of the abdomen to the time the patient was ready to move to the recovery ward was recorded (recovery time). After surgery, all airways were removed in the operating room before transfer of the patient to the recovery room. The recovery room staff recorded the incidence of early sore throats. The number of late sore throats was recorded after a telephone survey on the first postoperative day. Even mild sensations in the throat with minimal pain were recorded as sore throats.


    Airway insertion times
 TOP
 Abstract
 Introduction
 Materials and methods
 Airway insertion times
 Results
 Discussion
 References
 
The insertion of the airway was considered easy and uncomplicated if achieved within 15 sec. A second insertion, because of the wrong size having been chosen or because placement was not straightforward, would automatically fall outside the 15-sec period. The time for the insertion process was taken from the moment placement of the airway commenced to the generation of the first satisfactory breath of at least 7 mL·kg–1.

Quality of airway seal
In addition to recording peak airway inflation pressures, the quality of the airway seal was measured in two ways:

  1. Airway sealing pressure was measured using a manometric stability technique.4 The maximum inflation pressure generated when using a gradual, slow manual inspiration over 1.5–2 sec with the expiratory valve closed and with the fresh gas flow into the circle absorber system limited to 2 L·min–1 was the value taken.
  2. The minimum flow rate required to keep the ascending bellows of the ventilator fully inflated was recorded.

Recovery time
In order to exclude variations in the surgical times, the recovery time was measured from the beginning of abdominal deflation until the patient was deemed by the anesthesiologist to be ready for transfer to the recovery room with the airway removed.

Statistics
Distribution of baseline variables was assessed by the Kolmogorov-Smirnov and Shapiro-Wilk W tests. For each study, parameter summary statistics were tabulated. Differences in baseline variables between study groups were compared using two-tailed t tests or the Mann-Whitney U test for continuous data, and Chi-square with Yates’ continuity correction for discrete data. Comparison among study group was performed by analysis of variance (ANOVA). If ANOVA was significant, the differences among the three groups were assessed by the Student-Newman-Keuls test to allow for multiple comparisons. For non-normally-distributed continuous data, the Kruskal-Wallis test (non-parametric ANOVA) and Dunn’s test for multiple comparisons were employed. A P value < 0.05 was considered statistically significant.


    Results
 TOP
 Abstract
 Introduction
 Materials and methods
 Airway insertion times
 Results
 Discussion
 References
 
There were no differences between groups with respect to age, weight, procedure time or Mallampatti score (Table IGo).


View this table:
[in this window]
[in a new window]
 
TABLE I Demographics and surgical times
 
The results are presented in Table IIGo. There was a high success rate for first time insertion with the PLMA (48/50) and the SLIPATM (49/50). From 150 24-hr follow-up telephone calls made to ascertain information regarding sore throats, 27 did not yield satisfactory information. Of the 27, 19 were not contactable the next day and the information from the other eight related to linguistic difficulties without suitable translators available. There was only one moderately severe sore throat reported in the TT group; otherwise all other sore throats were either mild or minimal in severity.


View this table:
[in this window]
[in a new window]
 
TABLE II Airway observations and recovery times
 

    Discussion
 TOP
 Abstract
 Introduction
 Materials and methods
 Airway insertion times
 Results
 Discussion
 References
 
This study demonstrates that both the PLMA and SLIPATM were used with complete success and were easy to insert; with respective first insertion success rates of 96% and 98%. The anesthesiologist inserting the airways was an experienced operator, having used each type of device over 100 times before the trial began. Nevertheless, an independent study has shown good success and ease of use of the SLIPATM even in inexperienced hands.5

We found that the TT sealed significantly better than both SLAs as demonstrated by the lower minimum flow rate into the absorber system. However, airway sealing pressures demonstrated SLA sealing qualities almost as good as those of a TT. The minimum flow rate required was well below 1 L·min–1 thus allowing low flow anesthesia. The difference between the two SLAs was not significant. After abdominal insufflation of the abdomen with CO2, the lower inflation pressures noted when using the TT may well be due to the use of the muscle relaxant. When comparing the TT with the SLAs, the differences in the rise in systolic pressures in response to airway placement was of a clinically important magnitude (> 15%). However, the SLIPATM and PLMA are associated with similar hemodynamic responses.

Interestingly, satisfactory conditions for ventilation were consistently achieved without muscle relaxants using both SLAs. Recovery time was significantly lower when using either SLAs compared with the TT. The time saved using the SLAs most probably relates to the avoidance of the need for muscle relaxants and the associated time for reversal and extubation.1 The mean time saved in the operating room based only on recovery time was greater than three minutes. Given the average time taken for each procedure (Table IGo), cumulative time saving could mean that, on average, one extra case per day could be performed in the day-surgery unit.

The combined incidence of both early and late sore throats showed that the PLMA caused the least sore throats. All sore throats recorded in the SLAs were mild or minimal in nature and required no treatment. There was only one moderate sore throat experienced by a patient in the TT group. The 9% loss to follow up related only to the 24-hr follow-up over the phone sore throat report. Considering that the patients were discharged the same day of the procedure (day surgery), we expected that we would be unable to contact some patients for the 24-hr follow-up. This is unlikely to be of clinical importance and, therefore, unlikely to have made an important difference to the final report.

The design of the PLMA is based upon the classical LMATM but with better maximum seal pressure, and it has a drainage tube, making it more suitable for laparoscopic work.6 However, it is not a single-use product. The SLIPATM is designed for single-use, and has a means of minimizing aspiration risk if regurgitation occurs.1 This relates to the large capacity within its hollow structure for entrapment of regurgitated liquids. Storage volumes (50mL)1 before aspiration occurred in the lung model were almost double the volume of the contents in fasted patient’s stomachs (26 mL).7,8 The effectiveness of the mechanism during a laparoscopy in the clinical part of the study was demonstrated in one patient who regurgitated 15 mL into the SLIPATM without any aspiration.1 As the reported incidence of aspiration with SLAs is very low, we can only know for certain that this proposed mechanism for preventing aspiration is reliable after it is widely used and perhaps after multicentre studies.

In conclusion, PLMA and SLIPATM SLA have been shown to be equally efficacious for use in gynecological laparoscopies without requiring muscle relaxants, with time-saving advantages and fewer side effects. There is less systolic pressure response to placement and fewer sore throats are experienced compared to airway management with a TT technique.


    Acknowledgments
 
The author (D.M.) is the inventor of the SLIPATM airway and was supplied with free samples from SLIPAmed SA Pty Ltd for the study.


    Footnotes
 
Funding sources and affiliations: Free samples of the airway were supplied from SLIPAmed SA Pty Ltd for the study. D.M. is both inventor of the SLIPATM airway and consultant to the manufacturer.

Accepted for publication August 19, 2005. Revision accepted September 15, 2005.


    References
 TOP
 Abstract
 Introduction
 Materials and methods
 Airway insertion times
 Results
 Discussion
 References
 
1 Miller DM, Light D. Laboratory and clinical comparisons of the Streamlined Liner of the Pharynx Airway (SLIPA) with the laryngeal mask airway. Anaesthesia 2003; 58: 136–42.[Medline]

2 Williams MT, Rice I, Ewen SP, Elliott SM. A comparison of the effect of two anaesthetic techniques on surgical conditions during gynaecological laparoscopy. Anaesthesia 2003; 58: 574–8.[Medline]

3 Piper SN, Triem JG, Rohm KD, Maleck WH, Schollhorn TA, Boldt J. ProSeal-laryngeal mask versus endotracheal intubation in patients undergoing gynaecologic laparoscopy. Anasthesiol Intensivmed Notfallmed Schmerzther 2004; 39: 132–7.[Medline]

4 Keller C, Brimacombe JR, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth 1999; 82: 286–7.[Abstract/Free Full Text]

5 Hein C, Plummer J, Owen H. Evaluation of the SLIPATM (Streamlined LIner of the Pharynx Airway), a single use supraglottic airway device, in 60 anaesthetised patients undergoing minor surgical procedures. Anaesth Intensive Care 2005; 33: 571–7.[Medline]

6 Maltby JR, Beriault MT, Watson NC, Liepert D, Fick GH. The LMA-ProSeal is an effective alternative to tracheal intubation for laparoscopic cholecystectomy. Can J Anesth 2002; 49: 857–62.[Abstract/Free Full Text]

7 Juvin P, Fevre G, Merouche M, Vallot T, Desmonts JM. Gastric residue is not more copious in obese patients. Anesth Analg 2001; 93: 1621–2.[Abstract/Free Full Text]

8 Maltby JR, Pytka S, Watson NC, McTaggart Cowan RA, Fick GH. Drinking 300 mL of clear fluid two hours before surgery has no effect on gastric fluid volume and pH in fasting and non-fasting obese patients. Can J Anesth 2004; 51: 111–5.[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
H. Hooshangi and D. T. Wong
Brief Review: The Cobra Perilaryngeal Airway (CobraPLA(R)) and the Streamlined Liner of Pharyngeal Airway (SLIPATM) supraglottic airways: [Article de synthese court : Les dispositifs supraglottiques Cobra Perilaryngeal Airway (CobraPLA(R)) et Streamlined Liner of Pharyngeal Airway (SLIPATM)]
Can J Anesth, March 1, 2008; 55(3): 177 - 185.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
D. Miller
Laryngeal Mask Airway Classic and Streamlined Pharynx Airway Liner Airway Comparison
Anesth. Analg., November 1, 2007; 105(5): 1508 - 1508.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Lange, T. Smul, P. Zimmermann, R. Kohlenberger, N. Roewer, and F. Kehl
The Effectiveness and Patient Comfort of the Novel Streamlined Pharynx Airway Liner (SLIPA(R)) Compared with the Conventional Laryngeal Mask Airway in Ophthalmic Surgery
Anesth. Analg., February 1, 2007; 104(2): 431 - 434.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Résumé de cet Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, D. M.
Right arrow Articles by Camporota, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, D. M.
Right arrow Articles by Camporota, L.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS