CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Prabhu, A.
Right arrow Articles by Cooper, R
Right arrow Search for Related Content
PubMed
Right arrow Articles by Prabhu, A.
Right arrow Articles by Cooper, R
Canadian Journal of Anesthesia 54:44518 (2007)
© Canadian Anesthesiologists' Society, 2007


Monday June 25; 1230 - 1400

44518 - RADIOGRAPHIC EVALUATION OF CERVICAL SPINE MOVEMENT DURING FLEXIBLE VIDEOBRONCHOSCOPY & LO-PRO GLIDESCOPE; A RANDOMISED CONTROLLED TRIAL

Atul Prabhu1, Daniel Wong2, Santanu Chakraborty3, E Massicotte4, G Tan5 and R Cooper6

1 University Health Network, Toronto Western Hospital, Toronto, ON, Canada
2 Toronto Western Hospital
3 Toronto Western Hospital
4 Toronto Western Hospital
5 Toronto Western Hospital
6 Toronto General Hospital

Abstract

INTRODUCTION: It is essential to prevent or minimize cervical spine movement in patients with c-spine injury. Flexible bronchospcopy (FB) is widely regarded as the gold standard for intubating patients with airway instability. The Lo-Pro Glidescope (LP-G) is a new improved video laryngoscope and may be associated with less c-spine movement. We aimed to compare c-spine movement using fluoroscopy during intubation with FB versus LP-G.

METHODS: After ethics board approval 28 consenting adults with no cervical spine abnormality were randomized to be intubated with either a FB or LP-G. Demographic data was collected. During intubation continuous video fluoroscopy of the cervical spine was performed. A neuroradiologist and a spine surgeon assessed c-spine movement independently. The primary endpoint was maximum angulations during the intubation sequence (Occ-C1, C1-2, C2-4, and C4-5). Power of the study was determined by considering a 1-degree change in angulations as significant. Mann Whitney U test was used to compare maximum range of motion and Wilcoxin signed rank test for interobserver differences.

RESULTS: No significant differences between FB and the LP-G groups in demographic data. Intubation times were comparable between LP-G (31+ 2 sec) and FB (31+ 3secs).


Figure 1

Max. change mean &#61617; SD, *p<0.05, **p<0.01

DISCUSSION: The Lo-Pro Glidescope has significantly greater movement that the Flexible bronchoscopy. This study has shown that there is some movement associated even with the Flexible Bronchoscopy.





This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Prabhu, A.
Right arrow Articles by Cooper, R
Right arrow Search for Related Content
PubMed
Right arrow Articles by Prabhu, A.
Right arrow Articles by Cooper, R


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS